TROUBLESHOOTING
Run On
“Run On” or “Carry On” is present in all Waterlogic pressure fed units without outlet solenoids.
“Run On” is defined as the amount of water that continues to dispense out of the faucet after
releasing the dispense button.
Run On exists because the tanks pressurize as water is being dispensed. Every Waterlogic tank has
an outlet restrictor to ensure the tanks remain full of water and water is controlled as it is released to
the faucet. The inlet solenoid controls flow into the tanks. The tanks will “depressurize” once the
dispense button is released the inlet solenoid closes. A small amount of water will “Run On” through
the faucet as the tank depressurizes to atmospheric conditions.
Typical “Run On” is 2-3 seconds.
“Run On” can be reduced by installing a pressure limiting device.
The amount of inlet or supply pressure directly impacts the amount of “Run On” as quantified below.
WLCP Lab Testing of Rn On 7-31-2013
Pressure
Pressure
Time
Flow Rate
Run On
Static PSI
Dynamic PSI
4 Liters
I/min
Seconds
68
40
61
2.9508197
3
50
30
72
2.5
2.5
32
20
92
1.956217
2
Pressure measured at inlet line to unit. Static with unit closed. Dynamic with unit dispensing cold
water.
No filters were installed in unit.
WL400
Operating, Installation, and Service Manual Page 72 - Revision: 5-29-2015
Содержание WL400 Series
Страница 15: ...BASE CABINET SIDE REMOVAL WL400 Operating Installation and Service Manual Page 15 Revision 5 29 2015...
Страница 16: ...BASE CABINET CONFIGURATION WL400 Operating Installation and Service Manual Page 16 Revision 5 29 2015...
Страница 19: ...RIGHT SIDE PANEL REMOVED WL400 Operating Installation and Service Manual Page 19 Revision 5 29 2015...
Страница 20: ...RO MEMBRANE INSTALLED WL400 Operating Installation and Service Manual Page 20 Revision 5 29 2015...
Страница 41: ...WL400 COUNTER TOP LAYOUT WL400 Operating Installation and Service Manual Page 41 Revision 5 29 2015...
Страница 42: ...WL400 BASE LAYOUT WL400 Operating Installation and Service Manual Page 42 Revision 5 29 2015...