VER 1.0 

 

PRODUCT SPECIFICATION 

 

 

 

 

 

 

 

CREATOR (CHINA) TECH CO., LTD. 

·

2F, M-10 Building, Center Area, Hi-tech Industrial Park , Shenzhen Guangdong China       

·

TEL:+86 755 26710691     FAX:+86 755 26710105 

·

Http://www.china-creator.com 

Summary of Contents for CRT-571

Page 1: ...ssuing Machine VER 1 0 PRODUCT SPECIFICATION CREATOR CHINA TECH CO LTD 2F M 10 Building Center Area Hi tech Industrial Park Shenzhen Guangdong China TEL 86 755 26710691 FAX 86 755 26710105 Http www china creator com ...

Page 2: ...CIFICATION 4 4 1 CARD THICKNESS ADJUSTMENT 4 5 SENSOR AND CARD STOP POSITION 5 6 MULTI UNIT COMMUNICATION SETTING 6 6 1 SKETCH MAP OF MULTI UNIT PCB 6 6 2 DIP SETTING OF UNIT ADDRESS 6 7 STRUCTURE AND DIMENSION DRAWINGS 7 8 MAINTENANCE AND CAUTIONS 8 8 1MAINTENANCE 8 8 2 CAUTIONS FOR SAFE USE 8 8 3 WARRANTY 9 ...

Page 3: ...Revision Log Version Revision Time Content 1 0 2010 1 25 First Release ...

Page 4: ...ovable stacker Removeable stacker with lock the cards can be locked in the removable stacker Removable stacker can be locked to the machine body to prevent stolen Concave style of card thickness adjustment Two card reading type options card reading independently or via third party device Multi units communication support Max 16 sets of CRT 571 Compact size and low cost one of the most compact card...

Page 5: ...t lock CRT 500 X5N Capability 500pcs Short stacker with lock CRT 500 X2L Capability 240pcs Short stacker without lock CRT 500 X2N Capability 240pcs Client Code 00 Standard Product XX Customized Product Function I Contact IC Card C RF Card E IC Card RF Card N No Module W Specified PCB Board Communication U USB R RS 232 Collection B Card Bin R Channel Bezel N NO J J Type Bezel Baffle at the bezel po...

Page 6: ...ard Dimensions Size 55 86mm Thickness 0 36 1 0m Weight 2 0 Kg Approx Dimensions Refer to Structure And Dimension Drawings Card Stacking Capability 120pcs in case of 0 76mm standard card Available to set to 500pcs max Card Pre Empty Detection 7 50pcs 2pcs Default setting 15pcs Enviromental Condition Operation 0 50 0 90 RH Without Condensing Storage 10 75 0 90 RH Without Condensing Lift Time 500 tho...

Page 7: ...ent and inaccurate gap adjustment defects With this feature CRT 571 is quite suitable for the unattended vending devices to dispense various cards of distinct thickness There are several steps to adjust the thickness of cards 1 Confirm the thickness of cards Raised type character are not involved in 2 Press the turn knob and turn around to the graducation pointed by the red arrow Seeing pictures b...

Page 8: ...d Card Stop Position Sensors and card stop position show as below Front side without holding card Front side holding card IC Contact Card stacker IC Card operation position RF Card operation position Sensor 6 Position 1 Sensor 6 Position 2 Card collection position Collection Clips IC Contact ...

Page 9: ...g table shows the Dip setting of Unit Address Multi switch 4 3 2 1 Corresponding address ON ON ON ON 00 ON ON ON OFF 01 ON ON OFF ON 02 ON ON OFF OFF 03 ON OFF ON ON 04 ON OFF ON OFF 05 ON OFF OFF ON 06 ON OFF OFF OFF 07 OFF ON ON ON 08 OFF ON ON OFF 09 OFF ON OFF ON 10 OFF ON OFF OFF 11 OFF OFF ON ON 12 OFF OFF ON OFF 13 OFF OFF OFF ON 14 OFF OFF OFF OFF 15 ...

Page 10: ...Model No CRT 571 SPECIFICATION Date 2010 01 10 Ver 1 0 Card Dispenser Page 7 10 7 Structure And Dimension Drawings The following diagram show the structure and dimension ...

Page 11: ... whether they are corresponding 8 2 Cautions For Safe Use 1 Ensure the power is off while repairing the whole machine 2 Notice the cathode and anode of the machine power while power on for the first time 3 Notice the Specification of JUMP when using for the first time because improper JUMP will cause work off or unpredictable status 4 Prohibit to inset or pull out the receptacle of the port when p...

Page 12: ...ale service after exceeding guarantee period We will take some material fee if need to replace fittings And we will take some upkeep in the follows situations although it is in guarantee period a Damage and trouble caused artificially b Damage and trouble caused by non professional operation c Damage and trouble caused by instability of user s power supply d Damage and trouble caused by force maje...