TROUBLESHOOTING
Dispenses Hot and Cold Water at the same time
Possible Reason
Solution
Hot or Cold solenoid is stuck
open.
Remove top cover.
Check Hot Solenoid: Dispense cold water and visually inspect
tubing for water flow from both tanks.
Check Cold Solenoid: Disconnect elbow from outlet of cold
solenoid. Select hot water and dispense (quickly releasing
dispensing button to avoid much water coming out of cold
solenoid.
Replace solenoid as necessary.
WL400
Operating, Installation, and Service Manual Page 63 - Revision: 5-29-2015