RESETTING THE OVERLOAD OR HIGH LIMIT SAFETY
1.
Turn off Green Heater/Compressor Switch on rear of unit.
2.
Unplug the Power Cord from rear of unit.
3.
Remove the Tower Cover Locking Screws and open Slide Locks for
Top Cover.
4.
Unlock both locks. Slide Top Cover forward and lift in front of top cover to open.
5.
Remove the 2 Phillips Screws from Left Side Panel (when standing
behind unit) and remove side panel.
6.
Check and press both thermal overload buttons on Hot Tank.
7.
Close, lock and replace Top Cover Screws
8.
Turn on Red Power Switch and Green Heater / Compressor
Switch.