Hot Water Coming out of Faucet Vent Hole
Possible Reason
Solution
Improper tubing attachment
from the tank to faucet or vice
versa.
Verify tubing is connected properly from tank outlets to
correct faucet attachments.
Hot Tank outlet hole is scaled
over.
Inspect and descale or replace hot tank.
Expansion chamber is not
sealed properly.
Replace the Hot Tank.
WL400
Operating, Installation, and Service Manual Page 59 - Revision: 5-29-2015