background image

 

 

 

NovoSoft 465 Series 

Water Softener Operation Manual 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 

Note: 
1.  Read all instructions carefully before operation. 
2.  Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified lubricant to all seals. 
3.  Unit is factory set 

for “Clean Water” application.  See factory settings for “Problem Water” on page 10. 

4.  This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or 

after the system. 

 
 
 

Rev 1, May 28, 2012 

 

 

 

 

 

 

 

 

 

 

 

Tested and Certified by the Water Quality 
Association to CSA B483.1. 

Canadian Head Office

 

655 Park St.

 

Regina, SK S4N 5N1

 

  

 

 

Eastern Sales & Distribution

 

20 Steckle Place, Unit 21

 

Kitchener ON N2E 2C3

 

Summary of Contents for NVO465-100

Page 1: ...for Clean Water application See factory settings for Problem Water on page 10 4 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate d...

Page 2: ...3 Main Valve Functions 4 General Installation 5 Start up Instructions 6 Level I User Programming 6 Level II User Programming 8 System Configuration 10 Maintenance 11 Valve Drive Assembly Exploded Vie...

Page 3: ...val of calcium and magnesium ions that produces soft water This valve is controlled with simple user friendly electronics displayed on a large LCD screen The main page displays the current date and ti...

Page 4: ...ORY SETTING 2 MANUAL Adjustable Cycles All of the valve cycles are fully adjustable 1 BACKWASH 2 BRINE RINSE 3 RINSE 4 REFILL NOTE Refer to Level Two User Programming for description of each mode Duri...

Page 5: ...the valve and joints when soldering pipes that are connected to the valve Failure to do this could cause damage to the valve 4 If the valve is not installed on the tank cut the 1 central pipe flush w...

Page 6: ...es or until the water is clear 6 Press any button to advance to the REFILL position Check that the valve is filling water into the brine tank Allow the valve to refill for the correct amount of time a...

Page 7: ...e is the number of people living in the home It is used to calculate the amount of water needed for daily use and the reserve capacity of the system 4 WATER HARDNESS This value is the maximum water ha...

Page 8: ...NUAL CAPACITY CALC mode the CAPACITY can be adjusted by the user In AUTOMATIC CAPACITY CALC mode the current calculated value is displayed but cannot be adjusted FORMULA CAPACITY UNIT CAPACITY WATER H...

Page 9: ...YS SALT SETTING 6 LBS CF3 REFILL FLOWRATE FACTOR 0 9 UNIT CAPACITY 99 000 GRAINS RESERVE CAPACITY 75 GAL PERSON METER CAPACITY BACKWASH 10 MINUTES BACKWASH 10 MINUTES BRINE RINSE 60 MINUTES BRINE RINS...

Page 10: ...75C 5 0 50 0 5 0 10 0 50 0 5 0 0 2 2 0 0 70 NVO465 100C 5 0 50 0 5 0 10 0 50 0 5 0 1 3 2 4 0 70 MODEL INJECTOR SIZE DRAIN LINE FLOW CONTROL GPM BRINELINE FLOW CONTROL GPM CLEAN WATER PROBLEMWATER VAL...

Page 11: ...nterclockwise Figure 14 Bypass Installation View Maintenance Adding Salt Use only crystal water softener salt Check the salt level monthly It is important to maintain the salt level above the water le...

Page 12: ...body Carefully remove the assembly and disassemble as shown in Figure 6 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriver Remove the injector thr...

Page 13: ...brine well located in the cabinet tank Alternative use 3 4 oz of common 5 25 household bleach 3 Start an immediate regeneration If screen is locked press MENU for 3 seconds to unlock To initiate an I...

Page 14: ...B 09 05056166 S crew S T4 2 12 Large W afer 1 B 26 05056002 I dl erG ear 1 B 10 05056141 W asher 4x12 1 B 27 05010031 M eterA ssem bl y 1 B 11 05056016 B ri ne R egul ator 1 05010046 M eterS trai n R...

Page 15: ...r 1 A 13 05056073 S eal 5 A 42 05056072 O R i ng 24 2 1 A 14 05056019 B nt65 V al ve B ody 1 A 43 05056103 I nj ectorS creen 1 A 15 05056063 O ri ng 78 74 5 33 1 A 44 05056027 I nj ectorN ozzl e 1 A 1...

Page 16: ...egeneration frequency 3 Inlet of control plugged due to foreign materal Remove piston and clean control valve 1 Air in water system Check well system for proper air eliminator control 2 Incorrect drai...

Page 17: ...ion is provided and then the warranty period shall be from the date thereof Life Time Year Guarantee on Mineral Tanks and Brine Tanks Novo Water Conditioning Products will provide a replacement minera...