background image

INSTALLATION & OPERATING GUIDE

BUNN-O-MATIC CORPORATION 

POST OFFICE BOX 3227

SPRINGFIELD, ILLINOIS 62708-3227

PHONE: (217) 529-6601    FAX: (217) 529-6644

To ensure you have the latest revision of the manual or to obtain the illustrated parts catalog, please visit

the Bunn-O-Matic website, at www.bunn.com.  This is absolutely FREE, and the quickest way to obtain

the latest catalog and manual updates.  Contact Bunn-O-Matic Corporation at 1-800-286-6070 to obtain

a paper copy of the required Illustrated Parts Catalog mailed via U.S. Postal Service.

46819.0000A    06/12   © 2012   BUNN-O-MATIC CORPORATION

Hot Water

Dispensers

Supercedes

10052.0000; 10010.0000; 10267.0000

10420.0000; 10889.0000; 39338.0000

39338.0001; 44306.0000

Summary of Contents for 10010.0000

Page 1: ...it the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the latest catalog and manual updates Contact Bunn O Matic Corporation at 1 800 286 6070 to obtain a paper copy of the required Illustrated Parts Catalog mailed via U S Postal Service 46819 0000A 06 12 2012 BUNN O MATIC CORPORATION Hot Water Dispensers Supercedes 10052 0000 10010 0000 10267 0000 1042...

Page 2: ...s to this warranty or to make additional warranties that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive op tion while the equipment is under warranty shall either 1 provide at no charge...

Page 3: ... 93 3 500 212 9 100 5 200 93 3 0 212 0 100 0 200 93 3 500 211 1 99 5 200 93 3 1000 210 2 99 0 200 93 3 1500 209 3 98 5 200 93 3 2000 208 4 98 0 200 93 3 2500 207 4 97 4 200 93 3 3000 206 5 96 9 199 92 8 3500 205 6 96 4 198 92 2 4000 204 7 95 9 197 91 7 4500 203 8 95 4 196 91 1 5000 202 9 94 9 195 90 6 5500 201 9 94 4 195 90 6 6000 201 0 93 9 194 90 0 6500 200 1 93 4 193 89 4 7000 199 2 92 9 192 88...

Page 4: ...Fill water tank before turning on thermostat or connecting appliance to power source Use only on a properly protected circuit capable of the rated load Electrically ground the chassis Follow national local electrical codes Do not use near combustibles FAILURE TO COMPLY RISKS EQUIPMENT DAMAGE FIRE OR SHOCK HAZARD READ THE ENTIRE OPERATING MANUAL BEFORE BUYING OR USING THIS PRODUCT THIS APPLIANCE IS...

Page 5: ...for Initial Set Up CE REQUIREMENTS This appliance must be installed in locations where it can be overseen by trained personnel For proper operation this appliance must be installed where the tem perature is between 5 C to 35 C Appliance shall not be tilted more than 10 for safe operation An electrician must provide electrical service as specified in conformance with all local and national codes Th...

Page 6: ...ected to a COLD WATER system with operating pressure between 20 and 90 psi 138 and 620 kPa from a or larger supply line A shut off valve should be installed in the line before the dis penser Install a regulator in the line when pressure is greater than 90 psi 620 kPa to reduce it to 50 psi 345 kPa The water inlet fitting is flare NOTE Bunn O Matic recommends tubing for installations of less than 2...

Page 7: ...ve the center rear panel and rotate the control ther mostat knob fully clockwise to the ON position and replace the panel 5 Plug in the dispenser and wait approximately twenty minutes for the water in the tank to heat The dispenser is ready for use INITIAL SET UP OHW CAUTION The dispenser must be unplugged throughout the initial set up except when specified in the instructions 1 Place an empty ves...

Page 8: ...d the hidden programming button c located under the next to the BUNN logo on the front of the dispenser until the 3 LED s begin flashing from the left to the right Release the button 2 Place an empty graduated container under the dispense nozzle e 3 Press and release the batch size to be set a The LED s will stop flashing and the LED over the button just pressed will come on steady Water will begi...

Page 9: ...e center button The display will now show the model number ex H5H Now scroll with the buttons through the models listed above until the display matches the model you are working with 3 Press and release the center button once more The display will show P2 Display will now show the tank temperature ex 200 Press the button to increase the temperature set point or the button to decrease the set point...

Page 10: ... Degrees in Centigrade 2 Press and release the or buttons to alternate between FAH and CEn 3 AftersettingFAHorCEn toexitLevel2Programming pressandreleasethecenter button twice Display will show software version then model number then H3 RESTORING FACTORY DEFAULTS 1 To restore Factory Defaults This clears all settings that were previously entered press and release the center button untilH2 appears ...

Page 11: ... indicate it is in the energy save mode 3 Repeat procedure to exit energy save mode Programming the dispenser 1 Press and hold upper hidden button bottom center of BUNN logo until P1 is displayed Adjusting temperature The switch must be in the SET position in order to access the program modes 1 Press and hold TEMP button until display flashes 2 While display is flashing press and release the to in...

Page 12: ...pper hidden button once more The display will read P3 then show the ready temperature set point Range 2 to 20 below the SET temperature 5 Press the button to increase or the button to decrease the set point 6 Press and release the upper hidden button once more The display will read P4 This screen will allow you to turn the Auto energy save mode ON OFF NOTE Turning off this function will disable P5...

Page 13: ... all settings that were previously entered press and release the upper hidden button until H2 appears on the display ap proximately 6 seconds Release the upper hidden Button then press and release the upper hidden Button once more The display will read H3 then show 2 Press and hold both and buttons to initiate the resetting of the factory default settings The display will flash on and off during t...

Page 14: ...ws and the top cover 4 Gently remove one of the grommets from the tank lid 5 Insert a tube to the bottom of the tank and syphon ALL of the water out CLEANING The use of a damp cloth rinsed in any mild non abrasive liquid detergent is recommended for cleaning all surfaces on Bunn O Matic equipment WALL MOUNTED INSTALLATION 5 GALLON MODELS ONLY If the dispenser is wall mounted the bottom of the disp...

Reviews: