Base oils
Use of virgin base stocks only is allowed, i.e. recycled or re-refined base oils are not
allowed.
CONDEMNING LIMITS FOR USED LUBRICATING OIL
When estimating the condition of used lubricating oil, the following properties along with the
corresponding limit values must be noted. If the limits are exceeded, measures must be
taken. Compare also with guidance values for fresh lubricating of the brand used.
Property Unit
Limit
Test
method
Viscosity
cSt at 40 °C
max. 25% decrease
max. 45% increase
ASTM D 445
Viscosity
cSt at 100 °C
max. 20% decrease
max. 25% increase
ASTM D 445
Water
% V/V
max. 0.30
ASTM D 95 or D 1744
Base Number
mg KOH/g
min. 20 in HFO operation,
max. 50% depletion in
LFO operation
ASTM D 2896
Insolubles
% m/m in
n-Pentane
max. 2.0
ASTM D 893b
Flash Point, PMCC
Flash Point, COC
°C
°C
min. 170
min. 190
ASTM D 93
ASTM D 92
CHANGE OF LUBRICATING OIL BRAND
In order to minimize the risk of lubricating oil foaming, deposit formation, blocking of
lubricating oil filters, damage of engine components, etc., the following procedure should be
followed when lubricating oil brand is changed from one to another:
•
If possible, change the lubricating oil brand in connection with an engine (piston)
overhaul
•
Drain old lubricating oil from the lubricating oil system
•
Clean the lubricating oil system in case of an excessive amount of deposits on the
surfaces of engine components, like crankcase, camshaft compartment, etc.
•
Fill the lubricating oil system with fresh lubricating oil
If the procedure described above is not followed, responsibility of possible damage and
malfunctions caused by lubricating oil change should always be agreed between the oil
company and customer.
APPROVED LUBRICATING OIL QUALITIES FOR WÄRTSILÄ 32 ENGINES
Should unapproved lubricating oils be used during the engine warranty period, and there
exist no agreement with the engine manufacturer about testing, the engine guarantee does
not hold.
Содержание PAAE051728
Страница 4: ......
Страница 18: ...Appendix B Welding Precautions 200640 00 6...
Страница 26: ...01 Main Data Operating Data and General Design 32 200634 01 01 8 W RTSIL 32...
Страница 60: ...Appendix A Environmental Hazards 200507 02A 10...
Страница 68: ...Page 7 7 Document No 4V92A0645 Rev j...
Страница 84: ...03 Start Stop and Operation 32 200402 04 03 12 W RTSIL 32...
Страница 98: ...04 Maintenance Schedule 32 200623 01 04 14 W RTSIL 32...
Страница 154: ...07 Tightening Torques and Use of Hydraulic Tools 32 200643 01 07 30 W RTSIL 32...
Страница 162: ...08 Operating Troubles Emergency Operation 32 200402 01 08 8 W RTSIL 32...
Страница 164: ...Specific Installation Data 2005 01 09 2...
Страница 178: ...10 Engine Block with Bearings Oil Sump and Cylinder Liner 32 200150 10 14 W RTSIL 32 34SG...
Страница 216: ...Appendix A Testing of cylinder tightness 32 200142 A 4 W rtsil 20 32 34...
Страница 226: ...13 Camshaft Driving Gear 32 200546 02 13 10 W RTSIL 32...
Страница 253: ...U tube manometer Fig 15 12 401508200050 32 200549 10 Turbocharging and Air Cooling 15 W RTSIL 32 15 19...
Страница 254: ...15 Turbocharging and Air Cooling 32 200549 10 15 20 W RTSIL 32...
Страница 274: ...16 Injection System 32 200627 01 16 20 W RTSIL 32...
Страница 280: ...Fuel System 32 200508 07 17 6 W RTSIL 32...
Страница 314: ...19 Cooling Water System 32 200050 19 14 W RTSIL 32...
Страница 394: ...23 Instrumentation and Automation 32 200115 II 23 60 W RTSIL 32...