WAGO-I/O-SYSTEM 750
Function Description
43
750-636/000-x00 DC Drive Controller 24V/5A
Manual
Version 2.1.0
Example 18 "Approach without CurrentControl_PWM":
Figure 28: Example 18, " Approach without CurrentControl_PWM"
A positioning operation without phase P4 or CurrentControl is possible if the
ShutDown_Distance value is set to 0. Another reason for the absence of phase P4
could be that the direction-dependent prestop is at least the length of the
configured ShutDown_Distance (ShutDown_Distance <= Prestop).
The following examples also use the CurrentControl_ON control bit. It can be set
or reset at any time during the motion cycle, but is only effective during phase P3.
Example 19, "Approach with CurrentControl_PWM =
f(Control.CurrentControl_ON), Version 1":
Figure 29: Example 19, "Approach with CurrentControl_PWM = f(Control.CurrentControl_ON),
Version 1"
The CurrentControl_ON can switch on CurrentControl_PWM after the start of
phase P3, as well as switch it off again.