WAGO-I/O-SYSTEM 750
Process Image
59
750-636/000-x00 DC Drive Controller 24V/5A
Manual
Version 2.1.0
Table 22: Status Byte S1
Status Byte S1
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Limit
Switch
_Pos
Limit
Switch
_Neg
Preset
Input
Current
Control
_ON
PWM_Act
ive
Extended
Info_On
Optimize
_On
Preset
Input
_Enabled
PresetInput
_Enabled
This bit indicates that the preset input is enabled.
0: Preset input is not enabled.
1: Preset input is enabled.
Optimize_On
This bit indicates the prestop optimization during the positioning
process.
0
Prestop is not optimized.
1
Prestop is optimized.
ExtendedInfo
_On
This bit indicates that the data in the input process image (byte 2 to 5)
was changed.
0: Extended status information disabled.
1: Extended status information enabled.
PWM_Active
This bit shows whether the I/O module at the motor output generates a
PWM signal.
0: No PWM signal at the motor output.
1: PWM signal at the motor output.
CurrentControl
_ON
This bit indicates if the motor final stage is operated with
CurrentControl_PWM.
0: Motor final stage is not operated with CurrentControl_PWM.
1: Motor final stage is operated with CurrentControl_PWM.
PresetInput
This bit indicates the input status of the preset switch.
0: Signal voltage (0) at the input.
1: Signal voltage (1) at the input.
LimitSwitch_Neg
This bit indicates the input status of the negative limit switch.
0: Signal voltage (0) at the input.
1: Signal voltage (1) at the input.
LimitSwitch
_Pos
This bit indicates the input status of the positive limit switch.
0: Signal voltage (0) at the input.
1: Signal voltage (1) at the input.