61
EPG-SPRINT
.
OPERATING MANUAL
VERSION 08/2010
ORDER NUMBER DOC 2305222
Parameter
Value
Designation
C16
External program selection
(pulse control using remote
control bush)
OFF
(factory setting)
The program is selected using 4 different
pulse lengths to select programs 1-4.
This setting is compatible with the
CCM Prima.
ON
The program is selected by using an
extended pulse/pause protocol to select
all 50 programs and call up the purge
function.
This setting should be used if control by a
programmable logic controller (PLC) is the
same as with a Profi Tech Sprint system.
For protocol, see service instructions for
EPG-SPRINT.
C17
Powder output
Increase the powder output
by switching the feed and
atomizing air in parallel. The-
se two air fl
ows must be
combined externally with a
Y piece and fed to the feed
air connection in the injector.
The additional quantity differs
depending on the injector
type. The atomizing and Tribo
air is no longer available to the
guns and must be supplied
from another source.
OFF
(factory setting)
“standard“ setting for separate hosing for
feed, dosage and atomizing air.
ON
The feed air and atomizing air outputs are
combined for a larger feed air quantity
(higher powder output quantity).
Attention: The Tribo and atomizing air is no
longer available.
C19
Delete created programs
NO
(factory setting)
No action.
res
All programs are reset to the delivery
condition if “res“ is saved with button 25.
C20
Reset unit to delivery
condition
NO
(factory setting)
No action.
res
All settings except programs are reset to
the delivery condition if “res“ is saved with
button 25..