44
EPG-SPRINT
.
OPERATING MANUAL
VERSION 08/2010
ORDER NUMBER DOC 2305222
Properties of the characteristic
Field of application/Remarks
Standard level (red)
●
Open-circuit voltage 100 kV
●
Maximum current 120 µA
(current limiting at 120 µA)
●
For poorly rechargeable types of
powder.
●
For high powder application.
●
For high application effectiveness.
●
This setting corresponds to the usual
Wagner high-voltage modules and
control
units.
Medium level (blue)
●
Open-circuit voltage 100 kV
●
Maximum current 120 µA
●
For small surfaces.
●
For well rechargeable types of powder.
●
For metal powder.
●
To reduce the effects of overcoating such
as craters and orange peel.
●
Increasing the open-circuit voltage
allows for a greater distance between
the spray gun and the workpiece while
maintaining sufficient powder charging.
Soft level (black)
●
Open-circuit voltage 100 kV
●
Maximum current 80 µA
●
For very well rechargeable types of
powder.
●
For small powder application.
●
For post-coatings.
Содержание EPG-SPRINT
Страница 2: ......
Страница 65: ...65 EPG SPRINT OPERATING MANUAL VERSION 08 2010 ORDER NUMBER DOC 2305222...
Страница 67: ......