62
EPG-SPRINT
.
OPERATING MANUAL
VERSION 08/2010
ORDER NUMBER DOC 2305222
Parameter
Value
Designation
C21
Vibrator motor control
after-run
10 s
(factory setting)
Vibrator motor overruns for 10 seconds.
OFF
Vibrator motor is not controlled; always
off.
ON
Vibrator motor is always switched on.
1 s - 240 s
Vibrator motor is switched on with the
manual gun‘s trigger lever and overruns
for X seconds; can be set from 1 second to
240 seconds.
C22
Hose rinsing (dosage air
without feed air)
OFF
(factory setting)
Hose purging switched off.
1 s - 10 s
Hose purging time overrun in seconds.
C23
Hose purging intensity of
dosing air
100%
(factory setting)
Hose purging intensity 100%.
1% - 100%
Hose purging intensity from 1 to 100%.
C25
Tribo current minimum
monitoring
OFF
(factory setting)
Tribo current is not monitored.
0.1 µA - 5 µA
If the Tribo current does not reach the
set values for more than 10 seconds, a
warning is issued (see Warnings and fault
messages).
C31-C40 Password protection
Password-protected; only for Wagner
personnel or appropriately trained
persons.
C41-C99 Password protection
Password-protected; only for Wagner
production sites or the Wagner Service
Center with appropriate test equipment.