26
EPG-SPRINT
.
P_01120
1
2
3
6
7
5
4
OPERATING MANUAL
VERSION 08/2010
ORDER NUMBER DOC 2305222
5.3.1
GROUNDING OF THE POWDER COATING SYSTEM
1
Only use mains cables with grounding strand!
2
Connect grounding cable with booth and system ground!
3
Connect grounding cable to an uncoated metal part of the booth!
4
Remove all paint from hooks and other hanger parts!
5
Do not wear non-conducting gloves!
6
Wear electrostatically conductive shoes!
7 The
fl oor must be electrostatically conductive!
8 Connect
fl oor and booth with system earth!