30
EPG-SPRINT
.
P_01177
OPERATING MANUAL
VERSION 08/2010
ORDER NUMBER DOC 2305222
6.3
AIR HIGH OUTPUT MODE (HIGH POWDER OUTPUT)
EPG-SPRINT can be used to combine the feed and atomizing air to achieve a higher feed air
volume. A high powder volume does however depend on other factors. The length of the
suction hose and the length and diameter of the powder hose also affect the maximum
powder volume.
6.3.1
COMBINING THE AIR OUTPUTS
A Y piece (order no. 9990149) is needed to combine the feed and atomizing air.
Attention:
●
The atomizing air is not available in this mode.
●
Warning messages 1-3 “insufficient feed air“, “insufficient dosage air“, “insufficient
atomizing air“ are deactivated in this mode.
Y piece