27
EPG-SPRINT
.
OPERATING MANUAL
VERSION 08/2010
ORDER NUMBER DOC 2305222
6
STARTING UP AND OPERATING
WARNING
Incorrect installation/operation!
Risk of injury and damage to equipment
When putting into operation and for all work, read and follow
the operating instructions and safety regulations for the addi-
tionally required system components.
SIHI_0050_GB
6.1
PREPARATIONS FOR STARTING UP
CAUTION
Equipment damage!
➞
The control unit must be connected and grounded according to the directions in
chapter 5.
➞
After switching on the unit, wait for the start up phase to be completed. A function
test is performed in the start up phase. At the end of the tests, the connected gun
type is detected and displayed.
➞
Do not actuate the trigger on a manual spray gun in the start up phase, if the gun
is used as a single device in a manual coating system. If the trigger is actuated, the
control unit will detect it as an automatic gun and wait for the actuation signal from
CCM Prima. The unit cannot be switched on.
6.1.1
GUN DETECTION
CAUTION
Faults!
➞
Do not operate the gun‘s trigger while the control unit is being switched on and is
powering up.
The EPG-SPRINT control unit automatically detects whether a manual or automatic gun
is connected to the control unit. It does this by checking whether the trigger switch is
activated when it is switched on.
●
If the trigger switch is pressed, the gun is an automatic one. The powder feed is
switched on and off by a primary controller (CCM 2007, CCM Prima or another original
Wagner device for controlling the EPG-SPRINT):
●
If the trigger switch is not pressed, the gun is a manual one. The powder feed is switched
on and off with the gun‘s manual trigger.