51
EPG-SPRINT
.
OPERATING MANUAL
VERSION 08/2010
ORDER NUMBER DOC 2305222
Fault numbers
Faults
Cause
Rectifi cation
E21-E25
Exception error.
●
Hardware defect has
occurred.
●
If problem persists,
contact
Wagner
Service
Team.
E31
Gun switch
monitoring in
automatic mode.
●
The gun switch line has
been
interrupted.
●
Gun unplugged during
operation.
●
Check gun cable.
●
Check gun.
E41
No fl ow of atomizing
air.
No air is fl owing out of the
control unit.
Causes:
●
Hose kinked / blocked.
●
Injector is not connected.
●
Compressed air switched
off.
Gun unplugged during
operation.
Check:
●
The hose laying.
●
The air supply to the
control
unit.
●
Input pressure >6bar.
●
Connect injector.
●
Open compressed air.
E42
No fl ow of dosage air.
No air is fl owing out of the
control unit.
Causes:
●
Hose kinked / blocked.
●
Injector is not connected.
●
Compressed air switched
off.
Gun unplugged during
operation.
Check:
●
The hose laying.
●
The air supply to the
control
unit.
●
Input pressure >6bar.
●
Connect injector.
●
Open compressed air.
E43
No fl ow of feed air.
No air is fl owing out of the
control unit.
Causes:
●
Hose kinked / blocked.
●
Injector is not connected.
●
Compressed air switched
off.
Gun unplugged during
operation.
Check:
●
The hose laying.
●
The air supply to the
control
unit.
●
Input pressure >6bar.
●
Connect injector.
●
Open compressed air.