Troubleshooting the Burner
Cub 200/300
56
ghi_tx001207gb.fm
Continued from the previous page.
6. Connect the machine to the power supply.
7. Hold the nozzle assembly facing into a container to catch the fuel spray.
8. Turn the machine on. If the machine is in a fault condition, press the RESET
(d)
button on the control panel.
9. After the 10-second prepurge cycle, the nozzle will spray fuel for approximately
1 second. Observe the spray pattern
(c)
.
Does the fuel spray form a consistent cone pattern?
Result
The nozzle now been checked. Reassemble the machine.
If the problem has not been resolved, continue with the next topic.
WARNING
Fire hazard. The fuel may ignite if there is an ignition source nearby. Fire can cause
severe injury or death.
f
Continue this procedure only when all sources of ignition have been removed
from the proximity of the machine.
Yes ____
No ____
The nozzle is OK.
The nozzle is dirty or damaged. Clean or
replace the nozzle.