Burner Setup
Cub 200/300
18
ghi_tx001317gb.fm
3.2
Setting Up the Burner
Factory
settings
Background
The burner consists of several different components and subsystems. Each of
these components or subsystems must be operating correctly for the burner to
function properly.
Fuel
Low ambient temperatures cause diesel fuels to gel. Gelled fuels will cause burner
ignition failure and/or burner fuel pump damage. Always use the proper fuel for the
conditions.
Note: The burner on this machine was calibrated by test-firing for correct operation
at Wacker Neuson Corporation located 180 m (600 ft.) above sea level using #2
diesel fuel combined with an anti-gelling additive.
Tools required
The following tools are required to adjust the burner:
High-quality combustion analyzer
Smoke spot tester
Fuel pressure test gauge
General hand tools
Mandates
Adjustments made shall be done so that the machine conforms to the require-
ments of local, state, and federal codes and authorities.
Adjustments shall be made at the job site.
This procedure continues on the next page.
Machine
Nozzle size
Fuel pressure
Air band
setting
gph
psi
bar
Cub 200
1.0 x 60°A
175
12
2
Cub 300
1.5 x 80°W
175
12
3
Cub 300HD
1.35 x 80°H
218
15
5
Fuel Blend Guide
Lowest expected ambient
temperature °F (°C)
Generator powered
Shore powered
Below 5 (-15)
50-50 blend of #2 diesel
and #1 diesel, plus
additives
OR
50-50 blend #2 diesel and
K1 kerosene, plus
additives
100% #1 diesel plus
additives
OR
100% K1 kerosene,
plus additives
5 to 25 (-15 to -4)
70-30 blend of #2 diesel and #1 diesel, plus additives
OR
70-30 blend of #2 diesel and K1 kerosene,
plus additives
Above 25 (-4)
Winter-blend diesel
Содержание Cub 200
Страница 1: ...Repair Manual Indirect Fired Air Heater Cub 200 Cub 300 0179422en 001 1009 0 1 7 9 4 2 2 E N...
Страница 4: ...Foreword Cub 200 300 ghi_tx001204gb fm 4...
Страница 15: ...Cub 200 300 Operation ghi_tx001205gb fm 15 Notes...
Страница 59: ...Cub 200 300 Schematic ghi_tx001210gb fm 59 7 Schematic 7 1 Cub 200 Cub 300 Schematic...
Страница 64: ...Ground Heaters Inc 1271 Judson Road Spring Lake MI 49456 Tel 231 799 9600 Fax 231 799 9500 Tel 877 799 9600...