![Wacker Neuson Cub 200 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/wacker-neuson/cub-200/cub-200_repair-manual_3123718054.webp)
Troubleshooting the Burner
Cub 200/300
54
ghi_tx001207gb.fm
6.7
Checking the Flame Head
Requirements
Power disconnected
Hand tools
Procedure
Perform the procedure below to check the flame head.
1. Disconnect the power cord from the power supply.
2. Remove the burner assembly. See topic
Removing/Installing the Burner
Assembly
.
3. Loosen the four screws
(a)
.
4. Turn the flame head
(b)
counterclockwise and pull it from the machine.
5. Clean the flame head if it is dirty or full of soot.
6. Replace the flame head if it is damaged.
Result
The flame head has now been checked.
If the problem has not been resolved, continue with the next topic.
WARNING
Electric shock hazard. High voltage exists inside the machine when the power cord
is plugged into a power supply. Electric shock can cause serious injury or death.
f
Disconnect the machine from the electric power supply before continuing this
procedure.