Continued from the previous page.
12.Turn the machine off.
13.Check the condition of the ignition wires
(g)
between the transformer
(h)
and the
flame head
(i)
. If the ignition wires are damaged, replace them.
14.Check the resistance of the ignition wires. They should measure approximately
1000 ohms. If the ignition wires measure OL, replace them.
Result
The procedure to check the ignition transformer is now complete. Reassemble the
machine.
If the problem has not been resolved, leave the machine disassembled and
continue with the next topic. Otherwise, reassemble the machine.