![Wacker Neuson Cub 200 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/wacker-neuson/cub-200/cub-200_repair-manual_3123718045.webp)
Cub 200/300
Troubleshooting the Burner
ghi_tx001207gb.fm
45
Continued from the previous page.
6. Check that the fuel heater is connected to terminals M7 and M12 of the control
board.
7. Connect the power cord to the power supply.
8. Turn on the machine.
9. Measure the voltage between terminals
M7
and
M12
of the control board.
Is 108–132 VAC measured?
Result
The fuel filter heater has now been checked. Reassemble the machine.
WARNING
Electric shock hazard. High voltage exists inside the control panel when the power
cord is plugged into a power supply. Electric shock can cause serious injury or
death.
f
Use extreme care and appropriate arc flash avoidance techniques when per-
forming this procedure.
Yes ____
No ____
The fuel filter heater has failed. Disconnect
the power supply and replace the fuel filter
heater.
The control board has failed. Disconnect
the power supply and replace the control
board. Recheck the fuel filter heater after
the new control board is installed.