Cub 200/300
Troubleshooting the Burner
ghi_tx001207gb.fm
39
6.1
Checking the Ignition Transformer
Requirements
Fuel solenoid disconnected
Procedure
Perform the procedure below to check the ignition transformer.
1. Begin this procedure with the power supply disconnected.
2. Open the access panel
(a)
.
3. Locate the fuel solenoid
(b)
and disconnect it.
4. Loosen the wingnut
(e)
and open the air lock as far as possible.
5. Connect the power supply.
6. Turn the machine on and observe the spark between the electrodes
(f)
.
Is a good, strong spark visible?
This procedure continues on the next page.
Yes ____
No ____
The ignition transformer is OK.
Continue.
Содержание Cub 200
Страница 1: ...Repair Manual Indirect Fired Air Heater Cub 200 Cub 300 0179422en 001 1009 0 1 7 9 4 2 2 E N...
Страница 4: ...Foreword Cub 200 300 ghi_tx001204gb fm 4...
Страница 15: ...Cub 200 300 Operation ghi_tx001205gb fm 15 Notes...
Страница 59: ...Cub 200 300 Schematic ghi_tx001210gb fm 59 7 Schematic 7 1 Cub 200 Cub 300 Schematic...
Страница 64: ...Ground Heaters Inc 1271 Judson Road Spring Lake MI 49456 Tel 231 799 9600 Fax 231 799 9500 Tel 877 799 9600...