Burner Setup
Cub 200/300
24
ghi_tx001317gb.fm
3.6
Setting the Air Band
Requirements
Machine shut down
Power disconnected
Procedure
Perform the procedure below to set the air band.
1. Shut down the machine and allow it to cool.
2. Disconnect the power cord from the power source.
3. Remove the two bolts and open the access panel
(a)
.
4. Loosen the wing nut
(b)
and slide the air band
(c)
as needed. The front edge
should line up with the graduations (markings) on the flame head
(d)
.
5. Tighten the wing nut.
Result
The air band has now been set.