Troubleshooting the Blower
Cub 200/300
36
ghi_tx001207gb.fm
Continued from the previous page.
Does the capacitor measure 45–55 µF?
6. If the capacitor checks OK but the motor still hums, the problem is with the
wiring from the motor to the capacitor. Check this wiring.
7. If the capacitor and the wiring check OK but the motor does not run, the motor
has failed. Replace the motor.
Result
The capacitor has now been checked. Reassemble the machine.
Yes ____
No ____
Continue.
The capacitor has failed; replace it.