Cub 200/300
Troubleshooting the Blower
ghi_tx001207gb.fm
31
5.2
Checking Power to/from the Control Board
Requirements
120 VAC power source
Multimeter
Machine’s fuse is OK
Procedure
Perform the procedure below to check power to/from the control board.
1. Remove the screws
(a)
that hold the control panel and pull the control panel
from the machine.
2. Remove the cover
(b)
from the control panel.
3. Connect the power cord to a 120 VAC power supply.
4. Turn the machine on.
This procedure continues on the next page.
WARNING
Electric shock hazard. High voltage exists inside the control panel when the power
cord is plugged into a power supply. Electric shock can cause serious injury or
death.
f
Use extreme care and appropriate arc flash avoidance techniques when per-
forming this procedure.