Troubleshooting the Burner
ghi_tx001207gb.fm
55
6.8
Checking the Fuel Flow from the Nozzle
Requirements
Container to catch fuel (5 gallon bucket)
Procedure
Perform the procedure below to check the fuel flow from the nozzle.
1. Disconnect the power cord from the power supply.
2. Disarm the ignition function of the control board by removing the wires from
terminals
M16
and
M17
.
3. Remove the nozzle assembly
(a)
from the flame head.
4. Remove the cad cell
(b)
.
5. Place the cad cell inside the flame head and cover it with a rag.
This procedure continues on the next page.
WARNING
Electric shock hazard. High voltage exists inside the machine when the power cord
is plugged into a power supply. Electric shock can cause serious injury or death.
f
Disconnect the machine from the electric power supply before continuing this
procedure.