Cub 200/300
Safety Information
ghi_si000343gb.fm
11
1.5
Safety Guidelines for Maintaining the Machine
Training
Only trained personnel should troubleshoot or repair electrical problems occur-
ring with the machine.
Cleaning
When cleaning and servicing the machine:
Keep the area around the burner free of debris such as leaves, paper, cartons,
etc.
Keep the machine clean and labels legible.
When cleaning the machine:
Do not clean the machine while it is running.
Never use gasoline or other types of fuels or flammable solvents to clean parts.
Fumes from fuels and solvents can become explosive.
Maintenance
guidelines
When maintaining the machine:
Keep the fuel lines in good condition and properly connected.
Allow the burner to cool before maintaining the machine.
Reinstall the safety devices and guards after repairs and maintenance.
Keep all electrical cords away from heat, oil, vibrating surfaces, and sharp
edges.
Inspect all electrical cords before each use and replace damaged cords.
Replacing
parts and
labels
When maintaining the machine:
Replace worn or damaged components.
Use only spare parts recommended by Wacker Neuson Corporation.
Replace all missing and hard-to-read labels.
Replace or repair electrical components with components that are identical in
rating and performance as the original component.
Accessories,
safety devices
and
modifications
When using the machine:
Use only accessories/attachments that are recommended by Wacker Neuson
Corporation.
When using the machine:
Never operate the machine if any safety devices or guards are missing or inop-
erative.
Do not defeat safety devices.
Do not modify the machine without the express written approval of the manufac-
turer.
Содержание Cub 200
Страница 1: ...Repair Manual Indirect Fired Air Heater Cub 200 Cub 300 0179422en 001 1009 0 1 7 9 4 2 2 E N...
Страница 4: ...Foreword Cub 200 300 ghi_tx001204gb fm 4...
Страница 15: ...Cub 200 300 Operation ghi_tx001205gb fm 15 Notes...
Страница 59: ...Cub 200 300 Schematic ghi_tx001210gb fm 59 7 Schematic 7 1 Cub 200 Cub 300 Schematic...
Страница 64: ...Ground Heaters Inc 1271 Judson Road Spring Lake MI 49456 Tel 231 799 9600 Fax 231 799 9500 Tel 877 799 9600...