S E C T I O N 5 – R E P L A C I N G C O M P O N E N T S
CAFFÈ MIO – OPERATION AND SERVICE
Page 86 of 110
R e p l a c i n g M a j o r C o m p o n e n t s
g)
Install the drip tray detection and overflow bracket onto the slots at the inside bottom of the
front door, and tighten the screws to secure the bracket in place. Make certain the probes and
switch arm are placed in their proper position.
h)
Once certain that all the wiring connections have been made, re-install the front board cover,
making sure it the mounting screw passes through the key-hole slot on the cover. Tighten the
screw to secure the cover in place.
7.
Re-install the inner door by aligning and sliding the inner door hinges onto the machine
cabinet hinges (note that these are the same hinges used for the front door).
8.
Re-install the drip tray assembly onto the front door.
Position of
Switch Arm
Position of
Overflow
Probes
Tighten
Tighten
Tighten
Front Board
Cover