The Switch accepts the power input voltage from 48~57V DC (or 24~57V DC for AW-IHT-
1270-24V).
✓
Insert the power cables into the terminal block located on the top of the device.
✓
Check the front-panel LEDs as the device is powered on to verify that the Power LED
is lit. If not, check that the power cable is correctly and securely plugged in.
Notice:
Turn off the power before connecting modules or wires.
-
The correct power supply voltage is listed on the product label. Check the voltage of
your power source to make sure that you are using the correct voltage. Do NOT use a
voltage greater than what is specified on the product label.
-
Calculate the maximum possible current in each power wire and common wire. Observe
all electrical codes dictating the maximum current allowable for each wire size. If
current go above the maximum ratings, the wiring could overheat, causing serious
damage to your equipment.
Reset Button
There has “Reset” button in front of Switch which can help to manually hardware reboot.
3.3.
LED Indicators
This Switch is equipped with Unit LEDs to enable you to determine the status of the Switch, as
well as Port LEDs to display what is happening in all your connections. They are as follows:
Unit LEDs
LED
Condition
Status
PWR
(Green)
Illuminated
Switch uses primary power
Off
Primary power off or failure
RPS
(Green)
Illuminated
Switch uses redundant power
Off
Redundant power off or failure
ALM
(Red)
Illuminated
External signal device will be activated through
terminal block ALM when any of all port links fails
Off
No alarm to report
POST
(Green)
Illuminated
Switch is ready or running
Off
Switch is not ready
SFP
(Green)
(9~12)
Illuminated
SFP port link-up
Blinking
Activity (receiving or transmitting data)
Off
Port disconnected or link failed
PoE
(Green)
(1~8)
Off
No power is feeding
Illuminated
Power feeding on PoE port
1000Mbps
(Green)
Illuminated
Ethernet link-up
Blinking
Activity (receiving or transmitting data)
Off
Port disconnected or link failed
Illuminated
Ethernet link-up