3- 11.4 Auto Checking
This page allows the user to specify the auto detection parameters to check the linking status
between PoE ports and PDs. When it detected the fail connect, will reboot remote PD
automatically.
Web Interface
To Display Power Over Ethernet Auto Checking in the web interface:
1. Click Configuration, PoE, and Auto checking.
2. Enable the Ping Check function.
3. Specify the PD’s IP address, checking interval, retry time, failure action and reboot time.
4. Click Apply to apply the change.
Figure 3-11.2: The PoE Scheduling
Parameter description:
Power Supply Configuration
Ping Check :
Enable Ping Check function can detects the connection between PoE port and power
device. Disable will turn off the detection.
Port :
This is the logical port number for this row.
Ping IP Address :
The PD's IP Address the system should ping.
Start up Time(sec) :
When PD has been start up, the Switch will wait Start up time to do PoE Auto Checking.
default: 60, range: 30-600 sec.
Interval Time(sec) :
Device will send checking message to PD each interval time. default: 30, range: 10-120
sec.
Retry Time :
When PoE port can't ping the PD, it will retry to send detection again. When the third time, it
Содержание AW-GEV-264A Series
Страница 66: ...User Manual rev 1 2 Aug 2015 66...
Страница 185: ...User Manual rev 1 2 Aug 2015 185 values...
Страница 197: ...User Manual rev 1 2 Aug 2015 197 Clear Clears the counters for all ports...
Страница 238: ...User Manual rev 1 2 Aug 2015 238 Updates the table starting with the entry after the last entry currently displayed...
Страница 243: ...User Manual rev 1 2 Aug 2015 243 Refresh Click to refresh the page...
Страница 323: ...User Manual rev 1 2 Aug 2015 323 6 Click the Save button to save your configuration...