                                                               Safety Interlock Switch with Guard Locking   

 

     

                                                                          

 

 

                   

                            

 

                 

 

            
                

  
 
 
           
 
           

          

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
     
 
   
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Installation: 
   

                                                                                                                                                                                                               

1. Installation of all interlock switches must be in accordance with a risk assessment for the individual application.  
    Installation must only be carried out by competent personnel and in accordance with these instructions. 

 

2. M5 mounting bolts must be used to fix the switch and actuator, the tightening torque to ensure reliable fixing is 4.0 Nm. 
   

To prevent loosening of the switch after installation, always fix the M5 mounting bolts with a thread-locking                                                                                                                              

   compound or secure using self locking nuts.  

   Tightening torque for the lid screws, conduit entry plugs and cable glands must be 1.5 Nm to ensure IP seal.  
   Only use the correct size gland for the conduit entry and cable outside diameter. 
   Tightening torque for the connection terminal screws is 0.7 Nm, max conductor size is 1.0 sq.mm.    
   The switch head position can be selected by removing the actuator, loosening the 4 head bolts and then rotating                                                                                                                         
   the head to the position required. Re-tighten the head bolts and then check actuator insertion and withdrawal. 
   Tightening torque for the head bolts is 1.5Nm. 
                
3. Always fit a mechanical stop to the guard to prevent damage to the front of the switch. 
    Set the actuator gap to 3mm when the guard is closed and against the stop. (See Fig. A.) 
    Use alignment guides to ensure that the actuator enters the switch without interfering with the sides of the switch aperture.                                                                                                                                
    Always fit the aperture plug to the unused entry aperture to prevent debris entering the switch mechanism. 
     
4. After installation check operation of all control circuits and the locking function. 
    For applications with a run down time after removing power, ensure that the correct timing allowance has elapsed before energising the solenoid. 
    LED 1 GREEN will illuminate when power is applied to A1 and A2 (solenoid feed).  
      

 

 

 

Hinged Guard                                            Sliding Guard 

Application and Operation: 

The switch is rigidly mounted to the frame of the guard or machine. The actuator is fitted to the moving part (frame) of the guard and is aligned to the switch entry aperture. The actuator profile is 
designed to match a cam mechanism within the switch head and provides a positively operated not easily defeatable interlock switch. When the actuator is inserted into the switch the safety 
contacts will close only when power is applied to the solenoid. This will then allow the machine start circuit to be enabled. When the solenoid power is removed the safety contacts are opened 
and the machine circuit is broken. 

IMPORTANT

: Any hazardous motion has to be controlled and a safe condition initiated in the event of power failure.                                                                                                                                         

P2L versions (power to lock) may not be suitable for machines with a running down

 time.  

 

 

 

 

KLM-P2L  Operating Instructions

 

 

     Fig. A 

   Plastic Body 

IMPORTANT NOTE: 
Read and understand these instructions before installing, operating, or maintaining this equipment. 

The product is designed to be a component of a customised safety orientated control system. It is the responsibility of the user to ensure the correct overall functionality of its systems and 
machines. IDEM, its subsidiaries and affiliates, are not in a position to guarantee all of the characteristics of a given system or product not designed by IDEM. 
 

 

8 actuator entry positions  
rotatable head 

 

Internal Terminal Connections:                     

 
A1        0V dc                                                                                                              
A2      24V.dc                     
 
11-12       Safety Circuit 1 – 

(must always be used)                         

 

 
21-22

 

Safety Circuit 2               

 
33-34       Signal Circuit Guard - (Closed when Guard is closed)      
 
43-44       Signal Circuit Guard - (Closed when Guard is open)                  
 
 
 

LED Function: 

 
Green        Solenoid Energised 
 

 

 