Troubleshooting
4-7
Strata RX
Operator’s Guide/Tech Ref Manual
E154
RXU Receive Signal error
•
Check to be sure transmitter is
operating. If not transmitting, this is
normal - there is no signal to receive.
•
Check connections between antenna
and RXU.
•
Check connections between RCU
and RXU.
•
Check settings of RX using Monitor
Screens and Command Screens.
Specifically check Channel, Offset,
and Frequency. Settings must match
transmitter settings.
•
Take actions to optimize RCL, SNR,
and BER. See Section 3.4.6 on
page 3-14.
•
Call for technical service.
If errors persist when tested on service
bench with known good signal source,
unit has suffered internal failure. Send
unit for service.
E155
RXU Temperature error
•
Check RX to be sure it is not too
close to sources of heat. Relocate RX
if possible.
•
Check to be sure RX has room
around it for air circulation. Move
objects preventing air flow.
•
Call for technical service.
If errors persist with proper location and
airflow, and correct power connected,
unit has suffered internal failure. Send
unit for service.
Table 4-3: Primary Error Codes (Continued)
Error Code
Meaning
Suggested Operator Action
Suggested Technical Staff Action
Содержание Strata RX
Страница 2: ......
Страница 10: ...Contents viii Strata RX Technical Reference Manual ...
Страница 14: ...Introduction 1 4 Strata RX Technical Reference Manual ...
Страница 114: ...Installation 6 18 Strata RX Technical Reference Manual ...
Страница 116: ...Repair 7 2 Strata RX Technical Reference Manual ...
Страница 144: ...Channels Frequencies A 12 Strata RX Operator s Guide Tech Ref Manual ...
Страница 150: ...Glossary B 6 Strata RX Operator s Guide Tech Ref Manual ...
Страница 174: ...Configurator Reference C 24 Strata RX Technical Reference Manual ...
Страница 182: ...Link Quality D 8 Strata RX Technical Reference Manual ...
Страница 186: ...Index iv CodeRunner 2 Technical Reference Manual ...