Routine Operation
3-10
Strata RX
Operator’s Guide/Tech Ref Manual
Using the Monitor Screens in Digital Mode
When the RX is being used to demodulate a digital signal and
provide audio and video output, it is in Digital Mode.
Since there is digital demodulation taking place, all the Monitor
Screens will be active. These screens will report the digital audio
and video demodulation status.
See Figure 3-8 for an overview of what is reported on these
Monitor Screens.
Settings, Detected, Measured, and Derived Values
In Digital operation, there are four types of values reported on
the Monitor Screens:
•
Detected
values, which the RX senses and automatically
configures to match the parameters of the incoming
signal.
Detected
values are:
-
Modulation
-
FEC (Forward Error Correction)
-
GI (Guard Interval)
-
Audio Type
•
Settings
, which are configured in the RX, and must be
manually set to match the incoming signal.
Settings
are:
-
Preset
-
Band, Channel, Frequency
-
COFDM Bandwidth
-
IF Filter
-
Color Bar
•
Measurements
are made by the RX on the incoming
signal, and consist of:
-
Received Carrier Level
•
Derived Values
are calculated by the RX based on
characteristics of the incoming signal. These are:
-
BER (Pre- and Post-Viterbi Bit Error Ratio)
-
SNR (Signal-to-Noise Ratio)
-
LQ (Link Quality)
Содержание Strata RX
Страница 2: ......
Страница 10: ...Contents viii Strata RX Technical Reference Manual ...
Страница 14: ...Introduction 1 4 Strata RX Technical Reference Manual ...
Страница 114: ...Installation 6 18 Strata RX Technical Reference Manual ...
Страница 116: ...Repair 7 2 Strata RX Technical Reference Manual ...
Страница 144: ...Channels Frequencies A 12 Strata RX Operator s Guide Tech Ref Manual ...
Страница 150: ...Glossary B 6 Strata RX Operator s Guide Tech Ref Manual ...
Страница 174: ...Configurator Reference C 24 Strata RX Technical Reference Manual ...
Страница 182: ...Link Quality D 8 Strata RX Technical Reference Manual ...
Страница 186: ...Index iv CodeRunner 2 Technical Reference Manual ...