Checking the fuse
1.
Switch OFF the power.
2.
Release the side closures and
pivot the control unit down.
3.
Remove cover
A
.
4.
Check fuse F1 (see connection and
wiring diagram).
Extension kit for heating circuit with mixer
Checking the rotational direction of the mixer motor
1.
Switch ON/OFF switch
A
at the
extension kit first OFF and then ON
again. The device will carry out the
following self-test:
&
Mixer "Close" (150 s)
&
Pump "ON" (10 s)
&
Mixer "Open" (10 s)
&
Mixer "Close" (10 s)
Repairs
(cont.)