Calling up code 1
Note
&
On weather-compensated control
units, codes are displayed as plain
text.
&
Codes that are irrelevant due to the
system equipment level or the set-
ting of other codes will not be dis-
played.
&
Heating systems with one heating
circuit without mixer and one heat-
ing circuit with mixer:
Initially, the possible coding
addresses "A0" to "d4" for the heat-
ing circuit without mixer A1 are
scanned; then the coding addresses
for the heating circuit with mixer M2
are scanned.
Press the following keys:
1.
K
+
L
simultaneously for
approx. 2 s.
2.
a
/
b
for the required coding
address; the address
flashes.
3.
d
to confirm.
4.
a
/
b
for the selected value.
5.
d
to confirm; the display
briefly shows "
accepted
"
(weather-compensated
control unit); the address
flashes again.
6.
a
/
b
for the selection of further
addresses.
7.
K
+
L
press simultaneously for
approx. 1 s; code 1 is ter-
minated.
Overview
Coding
Coding in the delivered condition
Possible change
System design
00:2
System version 1:
1 heating circuit without
mixer A1, with DHW
heating
00:4
System version 2, 5:
1 heating circuit with
mixer M2, with DHW
heating
00:6
System version 3, 4:
1 heating circuit without
mixer A1 and 1 heating
circuit with mixer M2, with
DHW heating
Code 1
46
Coding
56
92
682
GB
Содержание Vitodens 333-F
Страница 5: ...Keyword index 133 Index cont 5 Index 5692 682 GB ...
Страница 119: ...A1 Main PCB A2 Power supply unit Connection and wiring diagram external connections 119 Designs 5692 682 GB ...
Страница 123: ...Parts lists cont 123 Parts lists 5692 682 GB ...
Страница 124: ...Parts lists cont 124 Parts lists 5692 682 GB ...
Страница 125: ...Parts lists cont 125 Parts lists 5692 682 GB ...
Страница 126: ...Parts lists cont 126 Parts lists 5692 682 GB ...
Страница 127: ...Parts lists cont 127 Parts lists 5692 682 GB ...
Страница 128: ...Parts lists cont 128 Parts lists 5692 682 GB ...
Страница 135: ...Keyword index cont 135 Keyword index 5692 682 GB ...