Checking the condensate drain and cleaning the siphon
1.
Check that the condensate can
drain freely at the siphon.
2.
Pull retaining clip
A
off.
3.
Pull filler pipe
B
upwards.
4.
Pull off lute
C
downwards.
5.
Pull the condensate hose from lute
C
.
6.
Clean the siphon.
7.
Fill siphon with water and reassem-
ble.
Further details regarding the individual steps
(cont.)