22
5
P
4
3
1
2
6
2
8
7
Required devices
Pos.
Description
1
Heat pump
2
Primary pump (installed and connected)
3
Geothermal probes/geothermal collectors
4
Brine distributor for geothermal probes/collectors
5
Brine accessory pack
6
Brine pressure limiter (accessory, if no brine pressure limiter is connected,
insert a jumper across terminals 1X3.8 and 1X3.9 prior to commission-
ing)
7
Frost protection monitor of the AC-Box (if an AC-Box is connected, con-
nect the frost protection monitor in series with the brine pressure limiter)
8
Integral control unit
Note
For further information regarding the ter-
minal markings and PCBs, see
page 61.
Preparing for installation
Connections on the primary side type BWC (brine/water)
5368 522 UAE