149
Parameter
■ 600B
Operating instructions
Set DHW temperature 2
Parameter
■ 600C
Operating instructions
Temp. sensor 2
Parameter
■ 600E
A second temperature sensor offers an
improved utilisation of the DHW cylinder.
It is fitted below the top temperature sen-
sor.
This temperature sensor (lower) is used
as stop criterion for the once-only DHW
heating through the demand "max. DHW
volume" or in the switching stages
"Standard" or "Set temp. 2".
DHW heating is started with the
switch-
ing times stages
using the
upper
tem-
perature sensor, in case of
max. DHW
volume
using the
lower
temperature
sensor.
Access
■ "
Device settings
"
■ "
Programming
"
■ "
DHW
"
■
y
to
"Temp. sensor 2"
■
"YES"
or
"NO"
Standard setting
No
Setting range
Yes/No
Booster heater
Parameter
■ 6014
The DHW can be boosted either by an
electric booster heater (e.g. electric
immersion heater EHE) or by a second
heat source (control or enabling the
pump for the external heat source).
DHW control settings
DHW auxiliary function
5368 522 UAE
Service