152
Parameter
■ 7907
This setting determines, with what max.
output (stage 1, 2 or 3) DHW and heating
water will be boosted.
The available output is subject to the way
the instantaneous heating water heater
is connected.
Access
■ "
Device settings
"
■ "
Programming
"
■ "
Electric heater
"
■
y
to "
Max. e heating stage
"
■
l
or
m
Standard setting
3
Setting range
1 to 3
Settings explained:
1 max. 3 kW
2 max. 6 kW
3 max. 9 kW
Stage for power-OFF
Parameter
■ 790A
Setting of the output stage for the electric
heater (instantaneous heating water
heater) that will be enabled even during
power-OFF periods. The selected stage
and all those below it will be enabled.
Access
■ "
Device settings
"
■ "
Programming
"
■ "
Electric heater
"
■
y
to "
Stage at power-OFF
"
■
l
or
m
Standard setting
0
Setting range
0 to 3
Settings explained:
0 No electric heater installed or all
stages blocked.
1 max. 3 kW
2 max. 6 kW
3 max. 9 kW
Control settings, electric heater
Max. stage electric booster heater
5368 522 UAE