130
Separate document; menu tree
Control unit settings by the contractor
Only
those settings are described on the
following pages that are the
exclusive
domain of specialists operating at the
contractor level. A code must be entered
to access the contractor level.
Customer level parameters that are
explained in the
operating instruc-
tions
, are
not
explained here. However,
they are listed in the order in which they
appear in the control menu.
!
Please note
Incorrect operation at the con-
tractor level can result in damage
to the appliance and the heating
system. All modified values will
be accepted automatically.
Always observe the installation
instructions; failure to observe
these will void your warranty
rights.
Note
The contractor level remains active until
key "Standard display" is pressed
again or no operation took place for 30
min. This activates the user level.
Access
■ Should "fault messages" already be
displayed, these can be skipped with
key
"BACK"
.
■
Device settings
■
Access rights
■ Enabling the contractor level: "
Enter
code: 5243
"
■ Confirm twice with
"OK"
Note
■ The availability or display of the
parameters described depends on the
current device settings.
■ As identifier, all parameters are given
a 4-digit ID.
■ The parameter descriptions include
the following details:
– ID
– Parameter description
– Access in the menu tree
– Standard setting in the delivered
condition
– Possible setting range
Control unit settings
Menu structure overview – main menu
5368 522 UAE
Содержание Vitocal 300-G BW
Страница 57: ...57 6 1 2 4 3 5 A 5x Installation sequence Opening the heat pump 5368 522 UAE Installation...
Страница 188: ...188 VITOCAL 300 205 025 011 203 202 200 206 207 204 201 010 025 A 026 Parts lists Parts lists type BWC cont 5368 522 UAE...
Страница 194: ...194 VITOCAL 300 205 203 202 200 206 207 204 201 010 026 025 A 025 Parts lists Parts lists type BW cont 5368 522 UAE...
Страница 213: ...213 5368 522 UAE...
Страница 214: ...214 5368 522 UAE...
Страница 215: ...215 5368 522 UAE...