16
Total weight with filled DHW cylinder
Type AWT-AC
Weight in kg
241.A04
424
241.A07
424
241.A10
427
241.A13
427
241.B10
427
241.B13
427
Minimum room volume (to EN 378)
Type AWT-AC
Minimum room
volume in m
3
241.A04
2.7
241.A07
4.9
241.A10
6.1
241.A13
6.1
241.B10
6.1
241.B13
6.1
Minimum clearances
Note
When using the secondary circuit con-
nection set (accessory), maintain a wall
clearance of approx. 80 mm.
Minimum room height h
Installation
h in mm
■
Without
connection set for
pre-installation/DHW (ac-
cessories)
2250
■
With
connection set for
pre-installation/DHW (ac-
cessories)
2350
Observe engineering informa-
tion.
Vitocal technical guide
Handling
The cylinder module can be removed
during transport.
!
Please note
Avoid damaging the appliance
during handling.
Never
put weight on the top, front
or side panels of the appliance.
Installation sequence
Installing the internal unit
(cont.)
5546 699 GB
Содержание AWT-AC 241.A04
Страница 19: ...19 SLP N 9 11 aCH sG lJ 10 Installation sequence Installing the internal unit cont 5546 699 GB Installation...
Страница 20: ...20 X20 2x 16 17 2x 12 14 18 13 15 Installation sequence Installing the internal unit cont 5546 699 GB...
Страница 21: ...21 2x 4x 4x 6x 21 19 20 22 Installation sequence Installing the internal unit cont 5546 699 GB Installation...
Страница 89: ...89 Removing cover from programming unit if necessary 5 4 4x Troubleshooting Repairs cont 5546 699 GB Service...
Страница 104: ...104 0010 0009 0007 0002 0004 0008 0001 0005 0003 0006 Parts lists internal unit Casing internal unit cont 5546 699 GB...
Страница 165: ...165 5546 699 GB...
Страница 166: ...166 5546 699 GB...
Страница 167: ...167 5546 699 GB...