12
■ Never install closer than 3 m to path-
ways, downpipes or sealed surfaces.
The cooled air in the discharge area
creates a risk of ice forming when out-
side temperatures are below 10 °C.
■ The installation site must be easily
accessible, for example for mainte-
nance work: See "Minimum clearan-
ces".
Minimum clearances
A
B
b
d
a
c
Example: type AWT-AC 241.A04
A
Air intake
B
Air discharge
Type AWT-AC Dimensions in mm
a
b
c
d
Cable entry
above
ground
level
below
ground
level
241.A04
≥ 100
≥ 100
≥ 400
≥ 300
≥ 1000
241.A07
≥ 100
≥ 100
≥ 400
≥ 300
≥ 1000
241.A10
≥ 100
≥ 200
≥ 400
≥ 300
≥ 1000
241.A13
≥ 100
≥ 200
≥ 400
≥ 300
≥ 1000
Installation sequence
Installing the external unit
(cont.)
5546 699 GB