138
Solar
Parameter
Code
Delivered
condition
Commis-
sioning
Mainte-
nance/
Service
"Type solar control unit"
7A00
0
"Max. collector temperature"
7A01
1300
(
≙
130 °C)
"Start hysteresis solar circuit
pump"
7A02
70 (
≙
7 K)
"Stop hysteresis solar circuit
pump"
7A03
30 (
≙
3 K)
"Flow rate solar circuit for cal-
culating solar yield"
7A07
100 l/h
"Display message incorrect
circulation"
7A09
1
Electric booster heater
Parameter
Code
Delivered
condition
Commis-
sioning
Mainte-
nance/
Service
"Enable instantaneous heat-
ing water heater"
7900
1
"Enable electric heaters for
DHW heating"
7901
0
"Enable instant. heating water
heater for central heating"
7902
0
"Max. output instantaneous
heating water heater"
7907
3
"Output for instant. heating
water heater at power-OFF"
790 A 0
"Dual mode temp instant.
heating water heater"
790 B 500 (
≙
50 °C)
Commissioning/service reports
Control parameters report
(cont.)
5546 699 GB
Содержание AWT-AC 241.A04
Страница 19: ...19 SLP N 9 11 aCH sG lJ 10 Installation sequence Installing the internal unit cont 5546 699 GB Installation...
Страница 20: ...20 X20 2x 16 17 2x 12 14 18 13 15 Installation sequence Installing the internal unit cont 5546 699 GB...
Страница 21: ...21 2x 4x 4x 6x 21 19 20 22 Installation sequence Installing the internal unit cont 5546 699 GB Installation...
Страница 89: ...89 Removing cover from programming unit if necessary 5 4 4x Troubleshooting Repairs cont 5546 699 GB Service...
Страница 104: ...104 0010 0009 0007 0002 0004 0008 0001 0005 0003 0006 Parts lists internal unit Casing internal unit cont 5546 699 GB...
Страница 165: ...165 5546 699 GB...
Страница 166: ...166 5546 699 GB...
Страница 167: ...167 5546 699 GB...