146
Type AWT-AC
241.A04
241.A07
241.A10
241.A13
Air intake temperature
Cooling mode
■ Min.
°C
15
15
15
15
■ Max.
°C
45
45
45
45
Heating mode
■ Min.
°C
–15
–15
–15
–15
■ Max.
°C
35
35
35
35
Heating water
(secondary
circuit)
Contents
l
2.8
2.8
3.8
3.8
Minimum volume
l
25
50
50
50
Minimum flow rate (must be
maintained)
l/h
750
1000
1600
1600
Max. external pressure drop
(RFH) at minimum flow rate
mbar
450
400
450
450
kPa
45
40
45
45
Max. flow temperature
°C
55
55
55
55
External unit electrical val-
ues
■ Rated voltage, compres-
sor
1/N/PE 230 V/50 Hz
■ Max. operating current,
compressor
A
13.5
15.7
19.6
26.5
■ Starting current, compres-
sor
A
10.5
15
10
10
■ Starting current, compres-
sor with stalled armature
A
20
25
25
32
■ MCB/fuse protection
A
16
16
20
32
■ IP rating
IP
24
24
24
24
Specification
Specification
(cont.)
5546 699 GB
Содержание AWT-AC 241.A04
Страница 19: ...19 SLP N 9 11 aCH sG lJ 10 Installation sequence Installing the internal unit cont 5546 699 GB Installation...
Страница 20: ...20 X20 2x 16 17 2x 12 14 18 13 15 Installation sequence Installing the internal unit cont 5546 699 GB...
Страница 21: ...21 2x 4x 4x 6x 21 19 20 22 Installation sequence Installing the internal unit cont 5546 699 GB Installation...
Страница 89: ...89 Removing cover from programming unit if necessary 5 4 4x Troubleshooting Repairs cont 5546 699 GB Service...
Страница 104: ...104 0010 0009 0007 0002 0004 0008 0001 0005 0003 0006 Parts lists internal unit Casing internal unit cont 5546 699 GB...
Страница 165: ...165 5546 699 GB...
Страница 166: ...166 5546 699 GB...
Страница 167: ...167 5546 699 GB...