98
Maintenance and Care
IM-HC 599871 0321 RABS
X
Log in all thermostats with the new control unit and assign the circuit
hubs.
X
Carry out a connection test at the thermostats.
Without WLAN module (configuration level 1 and 2)
X
Use the thermostats to set the target room temperatures.
X
If applicable, set the power level at the powerheads.
With WLAN module (configuration level 3)
X
Start the operating software (
Software” on page 57) and do the Intro (enter the name of the
control unit and the room name).
X
Carry out new settings for all the rooms (e.g. target value, profiles),
operating states, temperature limits etc.
With WLAN module (configuration level 4)
X
Start the existing object in the user account at the server (in the
Devices overview).
INFO! The serial number of the new control unit is indicated for
the object, but without a name for the control unit.
X
Enter the name of the control unit and the room name.
INFO! The Room overview shows “No name set!”. Click on the
pen icon to change the name.
X
Carry out new settings for all the rooms (e.g. target value, profiles),
operating states, temperature limits etc.
8.3.9 Replacing the WLAN Module
2
1
1
2
Figure 70: WLAN module replacement
1 – WLAN module (e.g. defective, or new tenant)
2 – New WLAN module
X
Pull the mains plug of the control unit (switch mains voltage off).
X
Disconnect the defective WLAN module.
X
Connect the new WLAN module.
X
Reconnect the mains plug to the control unit.
X
Select the network of the WLAN module at the end device and click
“192.168.1.1” to start the operating software in the browser.
X
Set the control or connect to the home network.
Log-in process for configuration level 4 (operation of control units
via Internet (server)):