XX100-00-01 Rev 202 Surveyor1000 Camera Dome System
Maintenance
••••
45
Maintenance
The Surveyor1000 requires no scheduled maintenance, however, the Lower Domes require occasional
cleaning. The Chrome and Gold Domes are referred to as Metallized type domes. The Clear and Smoked
Domes are referred to as Acrylic type domes. All domes require careful handling and occasional cleaning.
Care and Cleaning of Metallized Domes
1. Always handle the Lower Dome by the flange and avoid touching the inside surface, as acid in a
fingerprint can etch the internal coating. Use the recommended cleaning procedure in Step 4.
2. If dust or dirt accumulates in the Lower Dome's interior, remove it with clean, dry pressurized air.
3. If spots, streaks or stains appear on the interior, they can be removed by rinsing with clean water and
drying with clean, dry pressurized air. Do not rub the inner surface.
CAUTION: Rubbing the inner surface of Metallized Lower Domes can cause permanent scratches that
may render the dome unusable.
4. If cleaning of the inner surface is necessary, use a wick. Make a wick by rolling a section of soft
microwave-safe (aluminum free) paper towel into a tightly wound tube and tear it in half. Moisten the torn
edge of the wick with a solution of isopropyl alcohol and water. Hold the Lower Dome upside down and
gently wipe the inner surface from the inside to the outer edge. Use a new wick for each 2 passes over
the dome.
5. Clean the Lower Dome's exterior with any soft, nonabrasive cleaning cloth and a cleaning agent suitable
for acrylic plastic. Either liquid or spray cleaner (wax suitable for fine furniture) is acceptable.
Care and Cleaning of Smoked and Clear Acrylic Domes
1. Always handle the Lower Dome by the flange and avoid touching the inside surface.
2. If dust or dirt accumulates in the Lower Dome's interior, remove it with clean, dry pressurized air.
3. If spots, streaks or stains appear on the interior or exterior, they may be removed with a solution of
isopropyl alcohol and water using a soft microwave-safe (aluminum free) paper towel. Dry with clean, dry
pressurized air.
4. Scratches or surface blemishes on the interior or exterior may be removed with a nonabrasive wax using
a nonabrasive cleaning cloth. Either liquid or spray cleaner (wax suitable for fine furniture) is acceptable.
CAUTION: Excessive rubbing of the Lower Dome surface can cause permanent scratches that may
render the dome unusable.
5. Clean all surfaces with any soft, nonabrasive cleaning cloth and a cleaning agent suitable for acrylic
plastic.
Fuse Replacement
Two fuses (F1 and F2) are located on the Communication/Power Supply Board. When necessary, replace
them with the following Fuse values:
F1: 2AG, 1.6 amp, 250 volt, slo-blo
F2: 2AG, 2.5 amp, 250 volt, slo-blo
Содержание surveyor 1000
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 30: ...24 Installation XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 40: ...34 Wiring XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 44: ...38 Configuration XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 46: ...40 Uninstalling the Surveyor1000 XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 50: ...44 Operation XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 54: ...48 Shipping Instructions XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 61: ...XX100 00 01 Rev 202 Surveyor1000 Camera Dome System Technical Information 55 Figure 37 Dimensions ...