XX100-00-01 Rev 202 Surveyor1000 Camera Dome System
Operation
••••
43
4. Press the PP ENTER key again. The PRESET LED display remains with the number 95. The monitor will
display the power-up test screen (Figure 33) for the duration of its initial testing.
5. The Surveyor1000 then switches to the opening screen (Figure 34). This screen will display the Camera
Dome Program version, current date/time, the current address and a request to send communications to
baud detect. Move the joystick or press buttons to send commands and commence auto-baud detect.
Troubleshooting
If the Surveyor1000 does not power-up correctly, check the following:
⇒
Verify, with a voltmeter, that 22 to 34 VAC is measured across TB1, pins 1 and 2. If not, check the
integrity of the power wiring. If less than 22 VAC is measured, it is probable that the power cable length is
too long. Check the maximum usable cable distance for the voltage input as stated in Table 7 of the
Technical Information Section. If 22 to 34 VAC is measured, return the Surveyor1000 back to factory for
service in accordance with the Shipping Instructions Section of this manual.
⇒
If the last screen displays and does not disappear, the Surveyor1000 is not communicating with the
control device. Verify that the Surveyor1000 address is selected on the control device. Sometimes
moving the joystick can begin communication. If communication cannot be established, check the
integrity of the control signal wiring. If all wiring is correct, swap the Camera Drive and re-check. If the
new Camera Drive communicates, return the Surveyor1000 back to the factory for service in accordance
with the Shipping Instructions Section of this manual.
⇒
If the Surveyor1000 is intermittently operational or operating independently, it is possible that the
communications (control) wiring is incorrect. Re-check proper placement of the Control and Response
signals on the Terminal Block or RJ-45 Connector. Also, verify that S2, switch 3 is set for Half Duplex in a
Half Duplex wired Surveyor1000.
⇒
If the Surveyor1000 powers up but does not display any video, it is possible that there is a poor video
cable connection. Verify that BNC connectors are attached at the Camera Dome and monitor/CPU. In
addition, verify that the cable is not damaged. It is common for the cable to be stretched or squashed
somewhere along its run. If possible, check the output locally, with a portable monitor, at ths actual
Camera Dome site.
Содержание surveyor 1000
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 30: ...24 Installation XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 40: ...34 Wiring XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 44: ...38 Configuration XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 46: ...40 Uninstalling the Surveyor1000 XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 50: ...44 Operation XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 54: ...48 Shipping Instructions XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 61: ...XX100 00 01 Rev 202 Surveyor1000 Camera Dome System Technical Information 55 Figure 37 Dimensions ...