10
••••
Installation
XX100-00-01 Rev 202 Surveyor1000 Camera Dome System
The Accessory Kit containing the RJ-45 to RJ-
45 10 foot (2.5 m) cable and RJ-45 Termination
Box can be used in this installation for the 4
alarms or relay. Since there is no access to
above ceiling space and the supplied cable is
limited to 10 feet (2.5 m), the Termination Box
must be mounted in an area with access. In
addition, the 10 foot (2.5 m) cable must be
routed discretely with the other cables or
through the Flexible Conduit Pipe. Refer to
Figure 6 for an example of using the supplied
cable and Termination Box in this situation.
The ceiling material must provide a surface of suitable strength for the Surveyor1000 weight of 4.5 lb (2.0 kg)
on the area of the two Flippers. Refer to the
Optional Independent Support
sub-section for installations
requiring additional support.
1. Mark, with the scribe, and cut a 7-3/8-inch (187 mm ) diameter hole in ceiling at the desired location.
Feed all Flexible Conduit Pipe or cables down through the hole.
2. Remove the Camera Drive from the Enclosure by loosening the 3 Captive Screws.
3. If cables are used without the use of Flexible Conduit:
a) Remove the Enclosure Top Cover by loosening the 3 screws and lifting it off. Then remove the
Conduit Fitting by loosening the Nut and sliding it out. Install the supplied Strain Relief Fitting in its
place and re-attach the Top Cover.
b) Hold the Enclosure near the hole in the ceiling and route approximately 9 inches (229 mm) of cables
through the Strain Relief Fitting. Tighten the 2 Strain Relief Fitting screws to compress the cables. Do
not over-tighten the screws and crush the cables.
NOTE: Connectors that do not fit through the Strain Relief Fitting must be cut off and re-terminated after
passing the cable through. It is recommended to pass any RJ-45 Connectors through the fitting first.
BNC type connectors do not fit through the fitting and must be terminated later.
3. If cables are channeled through Flexible Conduit:
a) Hold the Enclosure near the hole in the ceiling and route approximately 9 inches (229 mm) of Conduit
cables through the Conduit Fitting.
b) Insert the end of the Flexible Conduit Pipe into the Conduit Fitting and tighten the Clamp Screw.
NOTE: Connectors that do not fit through the Conduit Fitting must be cut off and re-terminated after passing
the cable through. It is recommended to pass any RJ-45 Connectors through the fitting first. BNC type
connectors do not fit through the fitting and must be terminated later.
4. Lift Enclosure up through ceiling hole, turn and tighten Flipper Screws.
5. Connect the Latch of the Camera Drive to the Enclosure’s Safety Cord Clip.
Figure 6
Typical use of Accessory Kit
Содержание surveyor 1000
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 30: ...24 Installation XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 40: ...34 Wiring XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 44: ...38 Configuration XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 46: ...40 Uninstalling the Surveyor1000 XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 50: ...44 Operation XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 54: ...48 Shipping Instructions XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...
Страница 61: ...XX100 00 01 Rev 202 Surveyor1000 Camera Dome System Technical Information 55 Figure 37 Dimensions ...