background image

 

 
 
 
 
 
 
 
 

 

Vicon Part No. 8009-8100-00-01 Section 1 Rev 202 

 

                                                           

XX100-00-01

   

 
 
 
 

Surveyor1000 Camera Dome System 

 

 

 

 

 
 
 
 
 
 
 

Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet 
your requirements or that the operation will be entirely error free or perform precisely as 
described in the documentation. This system has not been designed to be used in life-critical 
situations and must not be used for this purpose. 

 
 

Copyright © 2002 Vicon Industries Inc. All rights reserved. 
Product specifications subject to change without notice. 
Surveyor1000 and its logo are trademarks of Vicon Industries Inc. 
Vicon and its logo are registered trademarks of Vicon Industries Inc. 
 
 
 

VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788 

TEL: 631-952-CCTV (2288)  FAX: 631-951-CCTV (2288)  TOLL FREE: 800-645-9116 

24-Hour Technical Support: 800-34-VICON (800-348-4266) 

UK: 44/(0) 1489-566300  INFOFAX: 800-287-1207  WEB: www.vicon-cctv.com

 

Содержание surveyor 1000

Страница 1: ... in life critical situations and must not be used for this purpose Copyright 2002 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Surveyor1000 and its logo are trademarks of Vicon Industries Inc Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX ...

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...Camera Drive 3 Shroud 3 Lower Dome 3 Housing 3 Sunshield Housing Assembly 3 INSTALLATION 5 Quick Installation In Ceiling Model Ceiling Access 5 Quick Installation In Ceiling Model No Ceiling Access 6 Quick Installation Indoor Pendant 7 Quick Installation Outdoor Pendant 8 Detailed Installation 9 Use of the Provided Scribe 9 In Ceiling Mount Model 9 Indoor Pendant Model 18 Outdoor Pendant Model 21 ...

Страница 6: ...etting the End of Line Jumpers JP1 JP2 JP3 for RS 485 Protocol Operation 37 UNINSTALLING THE SURVEYOR1000 39 For an In Ceiling Installation 39 For a Pendant Installation 39 OPERATION 41 Initial Power Up 41 Verifying Proper Operation 42 Use of the Auto Baud Detect Feature 42 Troubleshooting 43 MAINTENANCE 45 Care and Cleaning of Metallized Domes 45 Care and Cleaning of Smoked and Clear Acrylic Dome...

Страница 7: ...stallation and operation of the Surveyor1000 Camera Dome The graphics and terminology used in this manual have been carefully selected to enable a clear and distinct understanding of the Surveyor1000 and its components This manual has been formatted to present distinct methods of installation for experienced and novice installers For Experienced Installers Start at the Quick Installation sub secti...

Страница 8: ...sing this supplied Termination Box and Cable Assembly The supplied Strain Relief Fitting is used as an alternate means of providing support for cables on the In Ceiling Mount Model when Flexible Conduit Pipe will not be used Refer to the In Ceiling Mount Model sub section of the Installation Section for details on installing this fitting The RS 485 jumpers are provided to configure the RS 485 prot...

Страница 9: ...to the top of the Camera Drive There are variations in camera type for format magnification and day night usage Shroud The Shroud is a 5 4 inch 137 mm textured black ABS plastic shell It has a 1 2 inch 30 5 mm slotted opening for the Camera This Shroud helps conceal the position of the Camera and snaps onto the Camera Drive Lower Dome The Lower Dome is an assembly comprised of a 5 9 inch 150 mm di...

Страница 10: ...4 Introduction XX100 00 01 Rev 202 Surveyor1000 Camera Dome System Figure 2 Surveyor1000 Indoor Pendant Figure 3 Surveyor1000 Outdoor Pendant ...

Страница 11: ...m Installation 5 Installation Choose the installation type based on the specific unit purchased In Ceiling Indoor and Outdoor Pendant Quick Installation In Ceiling Model Ceiling Access Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N ...

Страница 12: ...6 Installation XX100 00 01 Rev 202 Surveyor1000 Camera Dome System Quick Installation In Ceiling Model No Ceiling Access Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N ...

Страница 13: ...XX100 00 01 Rev 202 Surveyor1000 Camera Dome System Installation 7 Quick Installation Indoor Pendant Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N ...

Страница 14: ...8 Installation XX100 00 01 Rev 202 Surveyor1000 Camera Dome System Quick Installation Outdoor Pendant Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N ...

Страница 15: ...etween the lower ceiling and upper building frame This section details 2 methods of installation The first method can be used for ceilings with no access to the space above as in a typical hard material ceiling The second method is used for a ceiling with access as in the case of a dropped ceiling metal grid type All mounting hardware is provided From Below the Ceiling no access to the space above...

Страница 16: ...the Conduit Fitting by loosening the Nut and sliding it out Install the supplied Strain Relief Fitting in its place and re attach the Top Cover b Hold the Enclosure near the hole in the ceiling and route approximately 9 inches 229 mm of cables through the Strain Relief Fitting Tighten the 2 Strain Relief Fitting screws to compress the cables Do not over tighten the screws and crush the cables NOTE...

Страница 17: ... J3 with control signals as this will cause the Camera Dome Program to lock up upon power up 7 Reinstall the Terminal Blocks TB1 and TB3 into the Communication Power Supply Board at the proper block frames 8 Install the Video BNC cable connector to the Communication Power Supply Board s mating BNC Connector at location J1 9 Plug in all RJ 45 cable connectors to their corresponding mating connector...

Страница 18: ...g 11 Carefully align the 3 Camera Drive Captive Screws with their mating standoffs and insert the Camera Drive into the Enclosure When seated tighten the 3 Captive Screws 12 Lift the Lower Dome up to the Surveyor1000 and line up the 2 molded tabs on the Lower Dome with the 2 recesses on the inner Enclosure Refer to Figure 7 There are only 2 ways to align it 13 Insert the Plug on the Safety Cord in...

Страница 19: ...supplied cable and Termination Box in this situation Detailed installation instructions will follow The ceiling material must provide a surface of suitable strength for the Surveyor1000 weight of 4 5 lb 2 0 kg on the area of the two Flippers Refer to the Optional Independent Support sub section for installations requiring additional support 1 Mark with the scribe and cut a 7 3 8 inch 187 mm diamet...

Страница 20: ...ks Then strip approximately 0 25 inches 6 mm of insulation off of each individual wire c Make all connections to Terminal Blocks TB1 and TB3 with reference to Table 2 On TB3 the COMMAND IN CI and COMMAND IN CI connections must be used for Simplex operation For Half Duplex operation the additional signals RESPONSE OUT RO and RESPONSE OUT RO must also be used Insert each wire into its proper Termina...

Страница 21: ...communication and address DIP Switches as follows a If RS 422 Mode will be used 1 Set switches 1 8 on DIP Switch 1 S1 to Surveyor1000 s address as specified in Table 3 All addresses between 0 and 255 are valid address 0 is the same as camera number 256 2 Set switch 1 on DIP Switch 2 S2 to the appropriate video mode PAL OFF or NTSC ON Figure 9 Close Up View In Ceiling Configuration with Cables ...

Страница 22: ... either position as it does not affect Vicoax protocol operation 4 Set switch 4 on DIP Switch 2 S2 to either position as it does not affect Vicoax protocol operation NOTE DIP Switches labeled ON or CLOSED and OFF or OPEN have the same meaning 10 Lift the Lower Dome up to the Surveyor1000 and line up the molded tabs on the Lower Dome with the recesses on the inner Enclosure There are only 2 ways to...

Страница 23: ...s to access the clips 3 Adjust the position of the Caddy Rail Clips along the frame to obtain the best X position 4 Slide the assembly along the Caddy Rails to obtain the best concentric Y position Tighten the horizontal adjustment screws to secure the position 5 With the Ring concentric with the hole slide the ring vertically along the support slots to obtain the best flush fit in the ceiling The...

Страница 24: ...of suitable strength for the Housing and the Surveyor1000 weight of 6 0 lb 2 7 kg 1 Install the Mount in accordance with the Installation Manual included with the Mount or prepare the vertical 1 0 inch NPT Pipe 2 Feed all necessary cables through the back of the Mount and out the end of the 1 0 inch NPT Pipe 16 inches 406 mm in length 3 Lift the Housing up to the Mount or Pipe and feed the cables ...

Страница 25: ...3 into the Communication Power Supply Board at the proper block frames 10 Install the Video BNC cable connector to the Communication Power Supply Board s mating BNC Connector at location J1 11 Plug in all RJ 45 cable connectors to their corresponding mating connectors J2 and J3 WARNING Failure to insert the RJ 45 Connectors into the correct mating connectors can cause damage to the Communication P...

Страница 26: ...counterclockwise looking up until the arrow on the Installation Label is aligned with the arrow on the inside of the Housing as shown in Figures 14c and 14d 17 Push the Surveyor1000 straight up into the Housing as shown in Figure 14e Verify that the 2 slots on the Surveyor1000 snap into the Housing clips Do not use excessive force In the event that it does not snap easily remove the Surveyor1000 a...

Страница 27: ...ince the supplied cable is limited to 8 feet 2 4 m the Termination Box must be mounted within the immediate area of the Surveyor1000 The Mount must provide a support of suitable strength for the Sunshield Housing and the Surveyor1000 weight of 6 8 lb 3 0 kg 1 Install the Mount in accordance with the Installation Manual included with the Mount or prepare the vertical 1 0 inch NPT Pipe 2 Feed all ne...

Страница 28: ...Terminate the video coaxial cable with a BNC type male connector e Terminate the 8 conductor alarm cable or communication relay cable with an RJ 45 male connector if connectors J2 or J3 will be used WARNING If Vicoax mode is being used DO NOT wire TB3 or J3 with control signals as this will cause the Camera Dome Program to lock up upon power up 10 Reinstall the Terminal Blocks TB1 and TB3 into the...

Страница 29: ...ing 17 Turn the Surveyor1000 counterclockwise looking up until the arrow on the Installation Label is aligned with the arrow on the inside of the Housing as shown in Figures 17b and 17c 18 Push the Surveyor1000 straight up into the Housing as shown in Figures 17d and 17e Verify that the 2 slots on the Surveyor1000 snap into the Housing clips Do not use excessive force In the event that it does not...

Страница 30: ...24 Installation XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...

Страница 31: ... 422 protocol is used for single Camera Dome applications RS 422 signals are always active and do not have a tri state high impedance state The RS 485 protocol is used for multiple Camera Domes in a daisy chain configuration RS 485 signals are not always active and do have a tri state high impedance state Thus Surveyor1000 can be daisy chained to any other compatible RS 485 device including anothe...

Страница 32: ... CLOSED NC ACTIVE HIGH OPEN NORMALLY OPEN NO ACTIVE LOW CLOSED The active state can be programmed through the Surveyor1000 menu system These signals are connected to RJ 45 Connector J3 Alarm signals can be programmed for their status enabled disabled active level definition high low action reset function none preset aux on aux off or tour acknowledgment mode automatic manual and report status yes ...

Страница 33: ...e connectors do not fit through the fitting and must be terminated later NOTE If conduit pipe is not used the supplied Strain Relief Fitting must be installed in place of the one installed to provide sufficient cable strain relief 3 Maneuver all cables as shown in Figure 21 Looping all cables around the inside provides natural strain relief and prevents sharp bends which could lead to broken cable...

Страница 34: ...le must be just long enough to permit the Safety Cord to be the sole support of the Surveyor1000 when removed from the Housing and just short enough to prevent improper bunching of the cables when installing the Surveyor1000 into the Housing Refer to Figure 22 for Indoor or Outdoor Pendant Model mount cable installation details 1 With the Surveyor1000 hanging from the Housing route each cable from...

Страница 35: ...1 and J3 WARNING Failure to insert the RJ 45 Connectors into the correct mating connectors can cause damage to the Communication Power Supply Board upon power up 9 Place each cable into the Enclosure s Cable Retainer for the Outdoor version under the Fan Bracket as shown in Figure 23 The Safety Cord should now provide sole support of the Surveyor1000 and the cables should be slack and comfortably ...

Страница 36: ...minal block will resemble Figure 24 Feed the Control Cable into one of the sides and connect each wire to the appropriate screws Figure 26 is shown wired for typical Surveyor1000 duplex operation with no relay NOTE Upon initial installation of a ceiling mounted Surveyor1000 it is recommended to pass this RJ 45 Connector through the fitting first After this the remaining connectors that do not fit ...

Страница 37: ...erminal behind the remaining wires to prevent it from touching other terminals 4 Feed the Control Cable from the Control Unit CPU or previous Surveyor1000 into one of the sides of the Termination Box and connect each wire to the appropriate screws 5 Feed the remaining Control Cable from the next sequential Surveyor1000 into the opposite side of the Termination Box and connect each wire to the appr...

Страница 38: ...provides a convenient connection from open wires to open wires After the cable is passed through the Cable Fitting ceiling mounted Surveyor1000 only connect it to Termination Box s terminals When the cover of the Termination Box is removed the pre wired terminal block will resemble Figure 28 Feed the Control Cable into the side and connect each wire to the appropriate screws Use Table 1 to referen...

Страница 39: ...TERMINAL BLOCK POWER TB1 TB1 1 H Hot TB1 2 N Neutral TB1 3 No connection RJ 45 ALARM J2 J2 1 ALARM1 Alarm input 1 J2 2 VSSA Ground J2 3 ALARM2 Alarm input 2 J2 4 VSSA Ground J2 5 ALARM3 Alarm input 3 J2 6 VSSA Ground J2 7 ALARM4 Alarm input 4 J2 8 VSSA Ground TERMINAL BLOCK COMM TB3 TB3 1 VSSA Ground TB3 2 RO Response out TB3 3 CI Command in TB3 4 RO Response out TB3 5 CI Command in RJ 45 COMM REL...

Страница 40: ...34 Wiring XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...

Страница 41: ...4 is the protocol mode setting RS 485 ON or RS 422 OFF Each switch is numbered from 1 to 8 and marked to indicate the ON position Surveyor1000 will automatically detect the system s baud rate and will support 4800 9600 and 19 200 kb sec rates For RS 422 485 Mode 1 Set switches 1 8 on DIP Switch 1 S1 to Surveyor1000 s address as specified in Table 3 All addresses between 0 and 255 are valid address...

Страница 42: ...211 X X X X X 40 X X 126 X X X X X X 212 X X X X 41 X X X 127 X X X X X X X 213 X X X X X 42 X X X 128 X 214 X X X X X 43 X X X X 129 X X 215 X X X X X X 44 X X X 130 X X 216 X X X X 45 X X X X 131 X X X 217 X X X X X 46 X X X X 132 X X 218 X X X X X 47 X X X X X 133 X X X 219 X X X X X X 48 X X 134 X X X 220 X X X X X 49 X X X 135 X X X X 221 X X X X X X 50 X X X 136 X X 222 X X X X X X 51 X X X ...

Страница 43: ...veyor1000 to access the jumper sockets Refer to the Uninstalling the Surveyor1000 section of this manual 2 Install all 3 jumpers by pushing them over the 2 pins for each socket on a Surveyor1000 which is the only unit in a daisy chain or the last in line of a daisy chain 3 Reassemble the Surveyor1000 and proceed to the Operation section of this Manual for functional testing Refer to the Installati...

Страница 44: ...38 Configuration XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...

Страница 45: ... the Camera Drive and lower it from the ceiling It will hang from the Safety Cord Refer to Figure 31 3 If it is necessary to completely remove the Camera Drive disconnect the Safety Cord Clip and all cables For a Pendant Installation 1 Outdoor Pendant model only Loosen the 4 Trim Ring Screws from the Outdoor Lower Dome 2 Gently pull down on the Lower Dome s outside edge until it snaps out of place...

Страница 46: ...40 Uninstalling the Surveyor1000 XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...

Страница 47: ...nd configured in accordance with this manual 3 Switch the AC power on to the Surveyor1000 The monitor will display the power up test screen Figure 33 for the duration of its initial testing This test displays the status of the functions pan tilt zoom focus and the integrity of the memory NVRAM If any test fails FAIL displays in place of OK 4 Upon completion of these tests the Camera Drive moves sl...

Страница 48: ... PRESET LED display remains with the number 94 and the monitor displays the Surveyor1000 Main Menu as shown in Figure 35 5 Set up the Surveyor1000 as desired using the remote keypad Proper operation has been verified Use of the Auto Baud Detect Feature Entering Preset 95 will start the Auto Baud Detect feature It allows the Camera Dome to detect a new baud rate from the host controller without hav...

Страница 49: ...nual If the last screen displays and does not disappear the Surveyor1000 is not communicating with the control device Verify that the Surveyor1000 address is selected on the control device Sometimes moving the joystick can begin communication If communication cannot be established check the integrity of the control signal wiring If all wiring is correct swap the Camera Drive and re check If the ne...

Страница 50: ...44 Operation XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...

Страница 51: ...ter Hold the Lower Dome upside down and gently wipe the inner surface from the inside to the outer edge Use a new wick for each 2 passes over the dome 5 Clean the Lower Dome s exterior with any soft nonabrasive cleaning cloth and a cleaning agent suitable for acrylic plastic Either liquid or spray cleaner wax suitable for fine furniture is acceptable Care and Cleaning of Smoked and Clear Acrylic D...

Страница 52: ...it with the following type BT1 Model number CR1632 Lithium 3 VDC 125 mAh It will be necessary to replace the battery when upon power up the time is reset and the previous programming configuration is reset to factory defaults The battery is accessible on the Camera Drive Mechanism from the side where the battery can be seen Snap it out and replace with the fresh cell ...

Страница 53: ...m countries in Europe contact Vicon Europe Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem and c...

Страница 54: ...48 Shipping Instructions XX100 00 01 Rev 202 Surveyor1000 Camera Dome System NOTES ...

Страница 55: ...tter coverage Cable Types The most commonly used cable types are RG 59 U and RG 11 U Each is actually a family of cables with widely varying electrical characteristics some of which are not suitable for CCTV applications Choose a cable type by referring to the characteristics and maximum distances listed below The maximum distance for best picture refers to the distance between the camera and the ...

Страница 56: ...s Single twisted pair is also a suitable cable Choose a Belden cable type by referring to the characteristics and maximum distances listed below The maximum distance for the most reliable digital control refers to the distance between the CPU Keypad and the Camera Dome Assembly The characteristics of the cables in Table 6 should be used as a guideline when cables other than Belden are used Materia...

Страница 57: ...ent Indoor 1 2 A nominal Outdoor 2 0 A heater included Power Consumption Indoor 28 8 W nominal Outdoor 48 0 W nominal heater included Heat Equivalent Indoor 1 6 btu min 0 4 cal min Outdoor 2 7 btu min 0 6 cal min Note These figures represent the conversion of 100 of the electrical energy to heat Actual percentage of the heat generated will be less and will vary from product to product These figure...

Страница 58: ...ilable with 32 programmable events per tour Events may be preset positions alarm acknowledgement alarm or preset dwell times auxiliary function activation calling autotours tour repeat or chaining tours Preset Solving Speed 1 second nominal Preset Repeatability 0 3 maximum Alarm Capabilities 4 alarm inputs Individual input enable disable Alarm report to CPU enable disable Active level definition h...

Страница 59: ...l tri state outputs for daisy chain capability Control Display On screen menu driven system allowing full configuration of the Surveyor1000 Screen Titling Capabilities Programmable for Camera Preset Sector and Alarms Fixed for Relay function and lens status Camera 1 for each Preset 79 maximum Alarm 4 maximum Individual type enable disable 20 characters maximum Selectable position MECHANICAL Applic...

Страница 60: ...MODEL NUMBER PRODUCT CODE ENVIRONMENT CAMERA TYPE FORMAT MOUNT TYPE OPTICAL ZOOM TOTAL ZOOM LOWER DOME TYPE S1000 IC 7858 00 Indoor Color NTSC Ceiling 18x 216x not included S1000 IC C 7858 01 Indoor Color PAL Ceiling 18x 216x not included S1000 PEN 7859 00 Indoor Color NTSC Pendant 18x 216x not included S1000 PEN C 7859 01 Indoor Color PAL Pendant 18x 216x not included S1000 ENV 7860 00 Outdoor Co...

Страница 61: ...XX100 00 01 Rev 202 Surveyor1000 Camera Dome System Technical Information 55 Figure 37 Dimensions ...

Страница 62: ...rope Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 322 712 8780 Fax 322 712 8781 Far East Office Unit 5 17 F Metropole Square 8 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Отзывы: